ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Hua Wei
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhou, Q.
Right arrow Articles by Zhang, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhou, Q.
Right arrow Articles by Zhang, H.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 1995;60:1245-1248
© 1995 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Unidirectional Valve Patch for Repair of Cardiac Septal Defects With Pulmonary Hypertension

Qiwen Zhou, MD, Yongqiang Lai, MD, Hua Wei, MD, Ruiming Song, MD, Yafeng Wu, MD, Hong Zhang, MD

Department of Cardiac Surgery, Beijing Heart, Lung and Blood Vessel Medical Center, and Anzhen Hospital, Beijing, People's Republic of China

Accepted for publication June 3, 1995.


    Abstract
 Top
 Footnotes
 Abstract
 Introduction
 Material and Methods
 Results
 Comment
 Acknowledgments
 References
 
Background. Congenital septal defects with a large left-to-right shunt often cause pulmonary hypertension, which complicates surgical repair of the defects.

Methods. Twenty-four patients with congenital cardiac septal defects and severe pulmonary hypertension had operation to close the septal defect using a unidirectional valve patch during a 3-year period. The ratio of systolic pulmonary artery pressure to systolic arterial blood pressure was near to or more than 1.0 in all patients.

Results. Two patients died in the hospital after operation, and there have been no deaths during intermediate term follow-up. Mean pulmonary artery pressure decreased from 80 ± 12 mm Hg to 56 ± 18 mm Hg. The ratio of pulmonary artery pressure to systemic arterial pressure dropped from 1.1 ± 0.1 mm Hg to 0.7 ± 0.1 mm Hg. The unidirectional valve patch functioned allowing right to left shunting in 4 patients with a systolic pulmonary artery pressure more than systolic arterial blood pressure immediately after closure of a septal defect. The patch sealed or was effectively closed by the third postoperative day. There was impressive improvement in symptoms and exercise tolerance after operation during the 3-month to 3-year (mean, 1.1 year) follow-up period.

Conclusions. The unidirectional valve patch is useful for management of patients having operation to close cardiac septal defects in the presence of severe pulmonary hypertension.


    Introduction
 Top
 Footnotes
 Abstract
 Introduction
 Material and Methods
 Results
 Comment
 Acknowledgments
 References
 
See also page 1249.

Congenital heart disease with septal defects and a large left-to-right shunt often causes pulmonary artery hypertension. The course of disease is variable and depends on the size of the defect, the magnitude of the left-to-right shunt, and the pulmonary vascular response to increased pulmonary flow and pressure [1]. Pulmonary artery pressure is hyperkinetic in the early phase but may eventually become a fixed elevation associated with a fixed increase of pulmonary vascular resistance [2]. The clinical symptomatic manifestations are decreased exercise tolerance, cyanosis, congestive heart failure, often hemoptysis, and finally death (Eisenmenger's syndrome). Eisenmenger's syndrome has been defined hemodynamically by Wood [3] as: Pulmonary hypertension at the systemic level due to a high pulmonary vascular resistance (more than 800 dynes • s-1 • cm5) with reversed or bidirectional shunt through a septal defect. Patients having Eisenmenger's syndrome are often seriously handicapped and may be functionally improved by closure of the septal defect, although ``long-term'' survival may be unaltered. Unfortunately, ``short-term'' risk of death accompanying the operation is high. This report documents the experience of closure of septal defects in a group of patients with severe pulmonary hypertension using a univentricular valve patch (UVP) in an effort to reduce the risk of operation.


    Material and Methods
 Top
 Footnotes
 Abstract
 Introduction
 Material and Methods
 Results
 Comment
 Acknowledgments
 References
 
Patients
Twenty-four patients with congenital cardiac defects and severe hypertension underwent operation in our institute during the period from January 1, 1990, to December 31, 1993. There were 15 cases of isolated ventricular septal defect, 3 cases of ventricular septal defect in combination with atrial septal defect, 2 cases of ventricular septal defect in association with patent ductus arteriosus, 2 cases of patent ductus arteriosus and coarctation of aorta coexisted with a large ventricular septal defect, and 2 cases of isolated atrial septal defect. The age ranged from 5 to 28 years (average, 15.8 years). All patients had dyspnea on exertion. Cyanosis was present in 2 patients at rest and occurred with exercise in 19. Five patients reported hemoptysis. A systolic murmur was audible in 11 patients. The murmur was only grade I (soft) in 8 patients and it was absent in 5 patients. The second heart sound was increased at the left base in all patients. Eight patients were classified in New York Heart Association functional class II, 15 in class III, and 1 in class IV. The electrocardiogram showed right axis deviation in all patients. There was right ventricular hypertrophy in 16 patients and 8 showed biventricular hypertrophy. Chest roentgenogram showed dilation of the main pulmonary artery in all patients, with a tumor-like enlargement in 6 of them. Cardiothoracic ratio ranged from 0.45 to 0.67 (mean, 0.55 ± 0.1). Bidirectional shunt through the intracardiac or extracardiac defect was present in all patients by echocardiography and catheter flow studies. Cardiac catheterization showed the ratio of pulmonary to system flow ranged from 0.5 to 2.0 (mean, 1.2 ± 0.5), and was less than 1.0 in 10 patients. Calculated total pulmonary resistance ranged from 8 to 32 Wood units (mean, 16 ± 7 Wood units). Pulmonary resistance was more than 10 Wood units in 20 patients and in 7 of them it was more than 20 Wood units. Ratio of systolic pulmonary artery pressure to systolic systemic arterial blood pressure (SPAP/SABP) ranged from 1.0 to 1.3 mm Hg (mean, 1.1 ± 0.1 mm Hg) and in 22 patients it was equal to or more than 1.0 mm Hg. Mean pulmonary artery pressure ranged from 50 to 98 mm Hg (mean, 80 ± 12 mm Hg), and it was more than 80 mm Hg in 14 patients. Arterial oxygen saturation ranged from 82% to 93% (mean, 87% ± 4%), and was less than 90% in 17 patients. Biopsy of the lung was performed in the last 12 consecutive patients. Pulmonary vascular disease was graded by Heath-Edwards classification [4]. There was 1 patient in grade I, 9 in grade III, and 2 had grade IV pulmonary vascular disease.

Methods
Anesthesia was induced by thiopental infusion and intermittent positive-pressure ventilation with nitrous oxide, facilitated by muscle relaxants. Fentanyl was used for maintenance. Pressure in the pulmonary artery was measured by needle puncture before repair of the septal defect and at the completion of operation before closure of the wound. A flow-directed balloon catheter was inserted into the main pulmonary artery to monitor the hemodynamic changes continuously in 12 patients who underwent operation in 1993. Systemic blood pressure and central venous pressure were monitored in the radial artery and femoral vein. The unidirectional valve patch was used to close the ventricular septal defect (22 patients) or atrial septal defect (2 patients). Associated anomalies were corrected simultaneously. The UVP was constructed from a Dacron patch approximately as large as the defect to be closed. A hole about 0.5 to 1.0 cm in diameter was made in the patch somewhat off the center. A piece of quadrangular pericardium was attached by suture to the surface of the Dacron patch. The three edges of pericardium were continuously sutured and one edge was left unattached. This unattached edge of pericardium should provide a small opening, not to exceed 0.5 cm, and appropriate tension should be maintained on the pericardial edge so that the valve mechanism will not be loose and incompetent. Nevertheless, the tension should not be too great and completely attach the pericardium to the Dacron patch and lose its valve effectiveness (Fig 1Go). The pericardial flap valve is placed on the left side (systemic) of the defect.



View larger version (36K):
[in this window]
[in a new window]
 
Fig 1. . Construction of a unidirectional valve patch for closure of atrial septal defect from Dacron with a 0.5- to 1.0-cm hole somewhat off center. Three sides of the pericardial patch are attached and one side is open to function as a valve. The pericardial flap valve is placed on the left side (systemic) of the defect. This allows blood to flow from the right atrium (RA) to the left atrium (LA) or across the ventricular septum when used to close a ventricular septal defect.

 
Hemodynamics were monitored for 3 days postoperatively in the 12 patients having operation in 1993. Pulmonary artery and systemic artery blood pressures were surveyed continuously. Cardiac output was measured regularly by Fick's method and total pulmonary resistance was calculated. The function of the unidirectional valve was examined by echocardiography with an injection of 1% hydrogen peroxide solution into an arm vein. The SPAP was estimated with echocardiography by the tricuspid regurgitation method before and during follow-up after operation.

Sedation and oxygen supplement were considered to be important to these patients in the postoperative care. Prostaglandin E1 was the pulmonary vasodilator of choice. The support time of respiration using endotracheal tube and respirator-assisted ventilation ranged from 44 to 93 hours (average, 58 hours).

Results were presented as mean ± standard error of the mean. Paired t tests were used to assess the difference between data at each time point. Spearman's correlation tests were performed to evaluate the relationships. Values were considered to be statistically significant when p was less than 0.05.


    Results
 Top
 Footnotes
 Abstract
 Introduction
 Material and Methods
 Results
 Comment
 Acknowledgments
 References
 
Two patients died after the operation. These patients were among those treated in the initial application of UVP. One died of acute right heart failure at the fourth postoperative day and the other died at the second postoperative day because of respirator failure, although the hemodynamics had improved after operation. The perioperative mortality was 8.3%. One patient with patch dehiscence and left-to-right shunt required reoperation. Cerebral air emboli occurred in 1 patient who gradually recovered with supporting therapy.

The follow-up period was 3 months to 3 years (average, 1.1 ± 0.9 years). The symptoms of dyspnea on exertion were relieved, cyanosis disappeared, and hemoptysis did not reoccur. Functional class improved with 14 patients in class I and 10 patients in class II.

Hemodynamic changes after operation included a significant decrease in pulmonary artery pressure (mean pulmonary artery pressure, 56 ± 19 mm Hg versus 80 ± 12 mm Hg before repair) and in the SPAP/SABP, 0.7 ± 0.1 versus 1.1 ± 0.1 before repair (Table 1Go). Arterial oxygen saturation increased significantly after operation (mean, 96% ± 1% versus 88% ± 4% before operation; p < 0.001). Hemodynamics continuously monitored during and after operation in 12 patients treated in 1993 showed most change occurring intraoperatively and only a slight further decrease of pulmonary artery pressure and SPAP/SABP during the first 12 hours after operation.


View this table:
[in this window]
[in a new window]
 
Table 1. . Results of Closure of Cardiac Septal Defect in Patients With Pulmonary Hypertension
 
At the end of operation, SPAP exceeded SABP in 4 patients. Intraoperative epicardial echocardiography showed the unidirectional valve open and blood flowing from the right to the left ventricle. The unidirectional valve gradually closed with improvement of hemodynamics in the 12 patients having serial echocardiography. The unidirectional valve had closed in 5 patients by the third postoperative day and remained only slightly open in 7 patients.

Echocardiography at 2 weeks and 4 weeks after operation showed SPAP continued to decrease, but the diameter of the pulmonary artery did not change.


    Comment
 Top
 Footnotes
 Abstract
 Introduction
 Material and Methods
 Results
 Comment
 Acknowledgments
 References
 
The surgical treatment of congenital heart disease with severe pulmonary hypertension is controversial [2, 58]. Perioperative mortality to close septal defects is high (22.7% to 50%) [912]. Acute congestive heart failure, pulmonary hypertensive crisis, and acute respiratory failure are the principal causes of perioperative death. It has been generally accepted that operation to close the septal defect should not be performed when the pulmonary vascular resistance is more than 10 Wood units, the ratio of pulmonary to system flow is less than 1.5, and the arterial oxygen saturation is less than 90% [2, 5, 13].

Pulmonary artery pressure and pulmonary vascular resistance are always significantly elevated in the patients with Eisenmenger's syndrome. Operation to correct the congenital cardiac defect requires use of cardiopulmonary bypass, infusion of protamine, and other factors that could cause the release of vasoactive substances such as thromboxane A2 and catecholamines resulting in pulmonary vasoconstriction and acute pulmonary hypertension [1418]. Pulmonary hypertensive crisis can be associated with acute congestive heart failure and death after operation in some of these patients. The univentricular valve patch was designed to function like the fossa ovalis of the atrial septum. It provides the advantage of opening to allow some blood to flow from right to left during pulmonary hypertensive episodes. This is akin to reducing risk by the technique of fenestration of the atrial septum after Fontan-type operations, which has been extensively documented in the literature. This could prevent pulmonary artery hypertension from becoming refractory while maintaining systemic blood pressure with the aim of reducing risk of death after operation. When pulmonary artery pressure diminishes after operation and pressure gradients between the right and left sides of the circulation normalize, the unidirectional valve closes and blocks the left-to-right shunt. The pericardium eventually adheres to the Dacron patch producing secure closure of the septal defect.

The data presented in this study indicated that the UVP has been a useful adjunct to management of patients having operations to close cardiac septal defects in the presence of severe pulmonary hypertension. Low operative mortality (8.3%) in these difficult operations is compelling evidence. Subjectively, systemic arterial blood pressure appears to remain quite stable during operation and during the critical early postoperative period and general management of the patient was easier. Postoperative epicardial echocardiography demonstrated that the valve actually opened and blood flowed from right to left circulation especially in those critical cases where pulmonary artery pressure was higher than systemic artery pressure. Blood was also shown to flow from the right to the left ventricle through the unidirectional valve during the 12-hour period after operation. As cardiac function improved and hemodynamics became more stable 1 to 3 days after operation, echocardiography showed that the UVP gradually closed and became less important.

Other aspects of perioperative management were certainly as important as the UVP for these patients. An endotracheal tube was in place and the patients' ventilation was supported by a respirator until cardiopulmonary function was stable and adequate. The period of respirative support was long for all patients, ranging from 44 to 93 hours (average, 58 hours). Prostaglandin E1 was used liberally as the principal pulmonary vasodilator, because it is a relatively selective pulmonary vasodilator and had less effects to systemic circulation [19, 20]. Nitric oxide was not available for management of this group of patients and could be even more effective than the combination of the UVP and prostaglandin E1. Inotropic agents were infused as required through the left atrial catheter to reduce pulmonary vasoconstriction.

Echocardiography was used to monitor structure and cardiac function in the operating room, during the postoperative period, and later after invasive catheters were removed. Pulmonary hypertension is considered to be the most common cause of functional tricuspid regurgitation [21]. Quantitation of tricuspid insufficiency by Doppler ultrasound provided an accurate noninvasive estimate of pulmonary artery pressure [22, 23] in the postoperative follow-up of these patients. Echocardiography was also useful in monitoring flow direction patterns across the septal defect closed by the UVP. Echocardiography showed the UVP had ceased functioning by 3 days after operation and the cardiac defect was completely closed. Structural abnormality, such as size of the pulmonary artery, did not change during follow-up although hemodynamics improved dramatically.


    Acknowledgments
 Top
 Footnotes
 Abstract
 Introduction
 Material and Methods
 Results
 Comment
 Acknowledgments
 References
 
We express thanks to Donald B. Doty, MD, for assistance in preparation of the manuscript.


    Footnotes
 Top
 Footnotes
 Abstract
 Introduction
 Material and Methods
 Results
 Comment
 Acknowledgments
 References
 
Address reprint requests to Dr Zhou, Beijing Heart, Lung and Blood Vessel Medical Center, Anding Menwai, Beijing 100029, People's Republic of China.


    References
 Top
 Footnotes
 Abstract
 Introduction
 Material and Methods
 Results
 Comment
 Acknowledgments
 References
 

  1. Wells WJ, Lindesmith GG. Ventricular septal defect. In: Arciniegas E, ed. Pediatric cardiac surgery. Chicago: Year Book Medical, 1985:141–53.
  2. Arciniegas E. Ventricular septal defect. In: Glen WWL, ed. Thoracic and cardiovascular surgery. East Norwalk: Appleton-Century-Crofts, 1983:745–56.
  3. Wood P. The Eisenmenger syndrome or pulmonary hypertension with reversed central shunt. Br Med J 1958;2:701–9.[Medline]
  4. Heath D, Edwards JE. The pathology of hypertensive pulmonary vascular disease: a description of six grades of structural changes in the pulmonary artery with special reference to congenital cardiac septal defects. Circulation 1958;18:533–47.[Medline]
  5. Kirklin JW, Barratt-Boyes BG. Cardiac surgery. New York: John Wiley & Sons, 1986:599.
  6. Wagenvoort CA, Wagenvoort N. Pathology of pulmonary hypertension. New York: John Wiley & Sons, 1977:56.
  7. Yamaki S, Mohri H, Haneda K, Endo M, Akimoto H. Indication for surgery based on lung biopsy in cases of ventricular septal defect and/or patent ductus arteriosus with severe pulmonary hypertension. Chest 1989;96:31–9.[Abstract/Free Full Text]
  8. Steele PM, Ruster V, Cohen M, Ritter DG, McGoon DC. Isolated atrial septal defect with pulmonary vascular obstructive disease: long-term follow-up and prediction of outcome after surgical correction. Circulation 1987;76: 1037–42.[Abstract/Free Full Text]
  9. Hallman GL, Cooley DA, Wolfe RR, McNamara DG. Surgical treatment of ventricular septal defect associated with pulmonary hypertension. J Thorac Cardiovasc Surg 1964; 48:588–600.[Medline]
  10. Cartmail TB, Dushane JW, McGoon DC, Kirklin JW. Results of repair of ventricular septal defect. J Thorac Cardiovasc Surg 1966;52:486–9.[Medline]
  11. Friedli BG, Kidd BSL, Mustard WT, Keith JD. Ventricular septal defect with increased pulmonary vascular resistance. Am J Cardiol 1974;33:403–9.[Medline]
  12. John S, Korula R, Jairaj PS, Muralidharan S, et al. Results of surgical treatment of ventricular septal defect with pulmonary hypertension. Thorax 1983;38:279–83.[Abstract/Free Full Text]
  13. Guo JQ, Xue GX, Zhu XD, et al. Surgical treatment of congenital ventricular septal defect: a 21 years experience in 1187 patients. Chin Med J 1983;96:323–9.[Medline]
  14. De Souza CA, Spyt TJ. Release of vasoactive substance during cardiopulmonary bypass. Ann Thorac Surg 1992;56:397–8.
  15. Komai H, Yamamoto F, Tanaka K, et al. Increased lung injury in pulmonary hypertensive patients during open heart operations. Ann Thorac Surg 1993;55:1147–52.[Abstract]
  16. Nuttall GA, Murray MJ, Bowie EJW. Protamine-heparin-induced pulmonary hypertension in pigs: effects of treatment with a thromboxane receptor antagonist on hemodynamics and coagulation. Anesthesiology 1991;74:138–45.[Medline]
  17. Montalescot G, Lowenstein E, Ogletree ML, et al. Thromboxane receptor blockade prevents pulmonary hypertension induced by heparin-protamine reactions in awake sheep. Circulation 1990;82:1765–77.[Abstract/Free Full Text]
  18. Komai H, Yamamoto F, Tanaka K, Yagihara T, Kawashima Y. Prevention of lung injury during open heart operations for congenital heart defects. Ann Thorac Surg 1994;57:134–40.[Abstract]
  19. Heerdt PM, Weiss CI. Prostaglandin E1 and intrapulmonary shunt in cardiac surgical patients with pulmonary hypertension. Ann Thorac Surg 1990;49:463–5.[Abstract]
  20. Weesner KM. Hemodynamic effects of prostaglandin E1 in patients with congenital heart disease and pulmonary hypertension. Cathet Cardiovasc Diagn 1991;24:10–5.[Medline]
  21. Berger M, Haimowitz A, Tosh AV, Berdoff RL, Goldberg E. Quantitative assessment of pulmonary hypertension in patients with tricuspid regurgitation using continuous wave Doppler ultrasound. J Am Coll Cardiol 1985;6:359–65.[Abstract]
  22. Himelman RB, Stulbarg MS, Lee E, Kuecherer HF, Schiller NB. Non-invasive evaluation of pulmonary artery systolic pressure during dynamic exercise by saline-induced Doppler echocardiography. Am Heart J 1990;119:685–8.[Medline]
  23. Chow LC, Dittrich HC, Hoit BD, et al. Doppler assessment of changes in right-sided cardiac hemodynamics after pulmonary thromboendarterectomy. Am J Cardiol 1988;61:1092–7.[Medline]

Related Article

Invited Commentary
David A. Fullerton
Ann. Thorac. Surg. 1995 60: 1249. [Extract] [Full Text]



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. K. Choudhary, S. Talwar, and B. Airan
A simple technique of unidirectional valved patch for closure of septal defects.
J. Thorac. Cardiovasc. Surg., November 1, 2007; 134(5): 1357 - 1358.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. Zhang, S. Wu, J. Liang, G. Zhang, G. Jiang, M. Zhou, and X. Li
Unidirectional Monovalve Homologous Aortic Patch for Repair of Ventricular Septal Defect With Pulmonary Hypertension
Ann. Thorac. Surg., June 1, 2007; 83(6): 2176 - 2181.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
A. Afrasiabi, M. Samadi, and H. Montazergaem
Valved Patch for Ventricular Septal Defect With Pulmonary Arterial Hypertension
Asian Cardiovasc Thorac Ann, December 1, 2006; 14(6): 501 - 504.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
Y.-Q. Lai, Q.-W. Zhou, H. Wei, C. Zhang, and Z.-G. Zhang
Intrapulmonary Channel for One-Stage Correction of Aortic Arch Obstruction
Asian Cardiovasc Thorac Ann, October 1, 2006; 14(5): 402 - 406.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Takabayashi, H. Shimpo, K. Yokoyama, and M. Kajimoto
One-way valved patch repair in an adult with a hypoplastic right ventricle.
J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 693 - 694.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W. M. Novick, A. T. Gurbuz, D. C. Watson, V. V. Lazorishinets, A. N. Perepeka, I. Malcic, B. Marinovic, B. S. Alpert, and T. G. DiSessa
Double patch closure of ventricular septal defect with increased pulmonary vascular resistance
Ann. Thorac. Surg., November 1, 1998; 66(5): 1533 - 1538.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Ad, J. Barak, E. Birk, E. Snir, and B. A. Vidne
Unidirectional Valve Patch
Ann. Thorac. Surg., August 1, 1996; 62(2): 626 - 628.
[Full Text]


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Hua Wei
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhou, Q.
Right arrow Articles by Zhang, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhou, Q.
Right arrow Articles by Zhang, H.
Related Collections
Right arrowRelated Article


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS