ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goldstein, D. J.
Right arrow Articles by Beauford, R. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goldstein, D. J.
Right arrow Articles by Beauford, R. B.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2003;75:S42-S47
© 2003 The Society of Thoracic Surgeons


Supplement

Left ventricular assist devices and bleeding: adding insult to injury

Daniel J. Goldstein, MDa*, Robert B. Beauford, MDa

a Department of Cardiothoracic Surgery, Newark Beth Israel Medical Center, Newark, New Jersey, USA

* Address reprint requests to Dr Goldstein, Department of Cardiothoracic Surgery, Newark Beth Israel Medical Center, 201 Lyons Ave, Suite G5, Newark, NJ 07112, USA.
e-mail: dgoldstein{at}sbhcs.com

Presented at the Heart Failure & Circulatory Support Summit, Cleveland, OH, Aug 22–25, 2002.

Abstract

Bleeding is the most common postoperative complication after implantation of left ventricular assist devices, necessitating reoperation in up to 60% of recipients. The implications of massive blood transfusions are great and include infection, pulmonary insufficiency, increased costs, right heart failure, allosensitization, and viral transmission, some of which can prove fatal or preclude transplantation. Preoperative evaluation and preparation are essential, intraoperative hemostasis is imperative, and "shotgun" product replacement should be avoided. Adherence to protocols emphasizing "hemostatic readiness" could reduce the incidence of bleeding complications that pervade left ventricular assist device therapy and potentially improve current successes in bridging to transplantation.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
I. Apostolidou, M. F. Sweeney, E. Missov, L. D. Joyce, R. John, and R. C. Prielipp
Acute Left Atrial Thrombus After Recombinant Factor VIIa Administration During Left Ventricular Assist Device Implantation in a Patient with Heparin-Induced Thrombocytopenia
Anesth. Analg., February 1, 2008; 106(2): 404 - 408.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
R. F. Padera Jr. and F. J. Schoen
Pathology of Cardiac Surgery
Card. Surg. Adult, January 1, 2008; 3(2008): 111 - 178.