ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Thierry P. Carrel
Friedrich S. Eckstein
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carrel, T. P.
Right arrow Articles by Meier, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Carrel, T. P.
Right arrow Articles by Meier, B.
Related Collections
Right arrow Coronary disease

Ann Thorac Surg 2003;75:1434-1436
© 2003 The Society of Thoracic Surgeons


Original article: cardiovascular

Pitfalls and key lessons with the symmetry proximal anastomotic device in coronary artery bypass surgery

Thierry P. Carrel, MDa*, Friedrich S. Eckstein, MDa, Lars Englberger, MDa, Stefan Windecker, MDb, Bernhard Meier, MDb

a Clinic for Cardiovascular SurgeryUniversity Hospital, Berne, Switzerland
b Division of Cardiology, University Hospital, Berne, Switzerland

Accepted for publication November 14, 2002.

* Address reprint requests to Dr Carrel, Clinic for Cardiovascular Surgery, University Hospital Berne, CH-3010 Berne, Switzerland.
e-mail: thierry.carrel{at}insel.ch

BACKGROUND: Increasing practice of less-invasive coronary artery bypass surgery has generated a revival of automated methods to facilitate the creation of vascular connections during coronary artery bypass grafting procedures.

METHODS: We have reviewed our clinical experience with 107 patients who received at least one proximal Symmetry aortic connector from St. Jude Medical Anastomotic Technology Group (St. Paul, MN) to connect a saphenous vein graft to the ascending aorta, in whom the minimal follow-up is 6 months. Seventy-five patients were part of an observational study, and 32 patients were enrolled in a prospective randomized study to compare the anastomotic device with the conventional suture technique. Key lessons and pitfalls observed during loading and deployment as well angiographic findings are presented.

RESULTS: Hospital mortality was 0.9% (1/107); a 76-year-old woman suffered from cerebral complications and died after combined coronary artery bypass grafting and aortic valve replacement. Two connectors had to be removed because of leakage and one because of incomplete deployment. The residual 104 grafts connected to the ascending aorta were patent at the end of the operation (mean flow, 72 ± 29 mL/min). Fourteen patients from the prospective study have received 6 months of angiographic assessment so far. Forty-two grafts have been evaluated: all IMA grafts (n = 14) are patent. Four radial artery grafts have been studied: three are patent and one is occluded. Twenty-four vein grafts have been assessed: 11 were hand-sewn and 13 were connected to the aorta with the proximal connector system. Patency rate is not different between the two techniques, but there is an incidence of 38% (5/13) stenosis in the proximal vein graft segment in those patients with a proximal connector. No proximal hand-sewn anastomosis shows any significant stenosis.

CONCLUSIONS: The use of proximal devices allows ultra-fast connection of a bypass graft to the aorta. The handling of this device is simple, manipulations on the ascending aorta are minimized, and hemostasis is perfect. However, because stenoses have been observed in the vein graft close to the connector site, mid- and long-term patency rates have to be assessed in large prospective trials.




This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
H. Takemura, Y. Fukumoto, T. Miyauchi, K. Shimabukuro, M. Imaizumi, and N. Ishida
Easy Technique for Mounting the Heartstring System into the Sheath
Asian Cardiovasc Thorac Ann, October 1, 2007; 15(5): 444 - 445.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Bergmann, K. Meszaros, S. Huber, P. Oberwalder, H. Machler, G. Schaffler, R. Rienmueller, and B. Rigler
Forty-one-month follow-up of the Symmetry aortic connector system for proximal venous anastomosis
J. Thorac. Cardiovasc. Surg., July 1, 2007; 134(1): 23 - 28.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. G. Kachhy, D. F. Kong, E. Honeycutt, L. K. Shaw, and R. D. Davis
Long-Term Outcomes of the Symmetry Vein Graft Anastomosis Device: A Matched Case-Control Analysis
Circulation, July 4, 2006; 114(1_suppl): I-425 - I-429.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. S. F. Fischer, B. Phillips-Bute, M. Swaminathan, C. Milano, and M. Stafford-Smith
SymmetryTM Aortic Connector Devices and Acute Renal Injury: A Comparison of Renal Dysfunction After Three Different Aortocoronary Bypass Surgery Techniques
Anesth. Analg., January 1, 2006; 102(1): 25 - 31.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Skjelland, J. Bergsland, R. Lundblad, P. S. Lingaas, K. A. Rein, S. Halvorsen, J. L. Svennevig, E. Fosse, R. Brucher, and D. Russell
Cerebral microembolization during off-pump coronary artery bypass surgery with the Symmetry aortic connector device
J. Thorac. Cardiovasc. Surg., December 1, 2005; 130(6): 1581 - 1585.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Setina, A. Krchnakova, A. Mokracek, L. Pesl, and L. F. Bonilla
The Second-Generation Aortic Connector: Six Months' Angiographic Follow-Up
Ann. Thorac. Surg., August 1, 2005; 80(2): 695 - 699.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
A. A. Frazier, F. Qureshi, K. M. Read, R. C. Gilkeson, R. S. Poston, and C. S. White
Coronary Artery Bypass Grafts: Assessment with Multidetector CT in the Early and Late Postoperative Settings
RadioGraphics, July 1, 2005; 25(4): 881 - 896.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Vicol, M. Oberhoffer, G. Nollert, S. Eifert, P. Boekstegers, B. Wintersperger, and B. Reichart
First Clinical Experience With the HEARTSTRING, a Device for Proximal Anastomoses in Coronary Surgery
Ann. Thorac. Surg., May 1, 2005; 79(5): 1732 - 1737.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M. Dietrich, S. Martens, M. Kohlert, C. Herzog, M. F. Khan, G. Wimmer-Greinecker, and A. Moritz
Decreased intermediate term patency of automated proximal anastomoses evaluated by sequential ultrafast CT
Eur. J. Cardiothorac. Surg., April 1, 2005; 27(4): 579 - 583.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Melero, C. Porras, M. Such, E. Olalla, and J. Alonso
Severe Stenosis of Anastomoses by Using the Symmetry Aortic Connector System
Ann. Thorac. Surg., November 1, 2004; 78(5): 1831 - 1833.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. S. Eckstein
Reply
Ann. Thorac. Surg., November 1, 2004; 78(5): 1879 - 1879.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. Medalion, D. Meirson, E. Hauptman, L. Sasson, and A. Schachner
Initial experience with the Heartstring proximal anastomotic system
J. Thorac. Cardiovasc. Surg., August 1, 2004; 128(2): 273 - 277.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Redaelli, F. Maisano, G. Ligorio, E. Cattaneo, F.M. Montevecchi, and O. Alfieri
Flow dynamics of the St Jude Medical Symmetry aortic connector vein graft anastomosis do not contribute to the risk of acute thrombosis
J. Thorac. Cardiovasc. Surg., July 1, 2004; 128(1): 117 - 123.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
K. Okada, T. Sueda, K. Orihashi, and K. Imai
Early type A dissection with the aortic connector device
Eur. J. Cardiothorac. Surg., May 1, 2004; 25(5): 902 - 904.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. J. Cavendish, W. F. Penny, M. M. Madani, S. Keramati, O. Ben-Yehuda, D. G. Blanchard, E. Mahmud, A. Perricone, and S. Tsimikas
Severe ostial saphenous vein graft disease leading to acute coronary syndromes following proximal aorto-saphenous anastomoses with the symmetry bypass connector device: Is it a suture device or a "stent"?
J. Am. Coll. Cardiol., January 7, 2004; 43(1): 133 - 139.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 by The Society of Thoracic Surgeons.