ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Edward A. Pascoe
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Freed, D. H.
Right arrow Articles by Pascoe, E. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Freed, D. H.
Right arrow Articles by Pascoe, E. A.
Related Collections
Right arrow Valve disease

Ann Thorac Surg 2002;74:2022-2025
© 2002 The Society of Thoracic Surgeons


Original article: cardiovascular

Nineteen-millimeter prosthetic aortic valves allow normalization of left ventricular mass in elderly women

Darren H. Freed, MDa, James W. Tam, MDa, Michael C. Moon, MDa, Gregory E.J. Harding, MDa, Ejaz Ahmad, RDCSa, Edward A. Pascoe, MDa*

a Sections of Cardiac Surgery and Cardiology, University of Manitoba, Winnipeg, Manitoba, Canada

Accepted for publication July 22, 2002.

* Address reprint requests to Dr Pascoe, Z3031, St. Boniface General Hospital, 409 Tache Ave, Winnipeg, MB, Canada R2H 2A6

BACKGROUND: Implantation of small aortic valve prostheses has been reported to be associated with impaired left ventricular (LV) mass regression and incomplete resolution of symptoms although these data have been generated largely with male patients. Therefore we sought to determine the clinical and hemodynamic outcomes of female patients who received a 19-mm aortic valve.

METHODS: Between May 1995 and December 2000, 38 female patients (average age 73 years, range 42 to 89) underwent isolated aortic valve replacement (AVR; n = 22) or AVR plus coronary artery bypass graft surgery (CABG; n = 16) with a 19-mm aortic prosthesis. The average New York Heart Association (NYHA) class was 3.08 and of the 26 patients who had angina, 47.2% were in CCS class III or IV. Clinical and echocardiographic follow-up was done an average of 33.4 months (8 to 72) after surgery.

RESULTS: Operative mortality was 10.5%. Overall survival at an average of 33 months was 71.1%. The average NYHA class was 1.52 ± 0.34 postoperatively (p < 0.001 versus preoperative) and 95% had no anginal symptoms or were in Canadian Cardiovascular Society class I. The LV mass index showed significant regression (114 ± 11 g/m2 to 89 ± 9 g/m2, p = 0.001) despite an effective orifice area index (EOAI) of 0.64 ± 0.09 cm2/m2.

CONCLUSIONS: Despite a very small EOAI, elderly female patients with 19-mm prosthetic aortic valves can experience a satisfactory improvement in symptoms and normalization of LV mass. This finding suggests that small prosthetic aortic valves continue to have an application in contemporary cardiac surgical practice. The current perception of patient-prosthesis mismatch may need to be reconsidered for select populations.




This article has been cited by other articles:


Home page
ICVTSHome page
A. G. Cerillo, A. Assal Al Kodami, M. Solinas, P. Andrea Farneti, S. Bevilacqua, S. Maffei, A. Mazzone, and M. Glauber
Aortic valve surgery in the elderly patient: a retrospective review
Interactive CardioVascular and Thoracic Surgery, June 1, 2007; 6(3): 308 - 313.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
P Pibarot and J G Dumesnil
Prosthesis-patient mismatch: definition, clinical impact, and prevention
Heart, August 1, 2006; 92(8): 1022 - 1029.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. G. Dumesnil and P. Pibarot
Prosthesis-patient mismatch and clinical outcomes: The evidence continues to accumulate
J. Thorac. Cardiovasc. Surg., May 1, 2006; 131(5): 952 - 955.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
F. Dagenais, P. Cartier, P. Voisine, D. Desaulniers, J. Perron, R. Baillot, G. Raymond, J. Metras, D. Doyle, and P. Mathieu
Which biologic valve should we select for the 45- to 65-year-old age group requiring aortic valve replacement?
J. Thorac. Cardiovasc. Surg., May 1, 2005; 129(5): 1041 - 1049.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Tasca, F. Brunelli, M. Cirillo, M. Dalla Tomba, Z. Mhagna, G. Troise, and E. Quaini
Impact of the Improvement of Valve Area Achieved With Aortic Valve Replacement on the Regression of Left Ventricular Hypertrophy in Patients With Pure Aortic Stenosis
Ann. Thorac. Surg., April 1, 2005; 79(4): 1291 - 1296.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. G. Fuster, J. A. M. Argudo, O. G. Albarova, F. H. Sos, S. C. Lopez, M. B. Codoner, J. A. B. Minano, and I. R. Albarran
Patient-prosthesis mismatch in aortic valve replacement: really tolerable?
Eur. J. Cardiothorac. Surg., March 1, 2005; 27(3): 441 - 449.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R.-U. Kuehnel, R. Puchner, A. Pohl, M. O. Wendt, M. Hartrumpf, M. Pohl, and J. M. Albes
Characteristic resistance curves of aortic valve substitutes facilitate individualized decision for a particular type
Eur. J. Cardiothorac. Surg., March 1, 2005; 27(3): 450 - 455.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. Amarelli, A. Della Corte, G. Romano, G. Iasevoli, G. Dialetto, L. S. De Santo, M. De Feo, M. Torella, M. Scardone, and M. Cotrufo
Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis
J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 512 - 517.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Bottio, L. Caprili, D. Casarotto, and G. Gerosa
Small aortic annulus: The hydrodynamic performances of 5 commercially available bileaflet mechanical valves
J. Thorac. Cardiovasc. Surg., September 1, 2004; 128(3): 457 - 462.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Bottio, G. Rizzoli, G. Thiene, G. Nesseris, D. Casarotto, and G. Gerosa
Hemodynamic and clinical outcomes with the Biocor valve in the aortic position: An 8-year experience
J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1616 - 1623.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.