|
|
||||||||
Ann Thorac Surg 2002;74:2003-2009
© 2002 The Society of Thoracic Surgeons
a Department of Medicine, Division of Cardiology, University of Michigan, Ann Arbor, Michigan, USA
b Section of Cardiothoracic Surgery, Department of Surgery, William Beaumont Hospital, Royal Oak, Michigan, USA
c Section of Cardiothoracic Surgery, Department of Surgery, London Health Sciences Center, London, Ontario, Canada
d Section of Cardiothoracic Surgery, Department of Surgery, St. Thomas Hospital, Nashville, Tennessee, USA
e Section of Cardiothoracic Surgery, Department of Surgery, Herzzentrum Universitat Leipzig, Leipzig, Germany
* Address reprint requests to Dr Bach, University of Michigan, L3119 Womens0273, Ann Arbor, MI 48109, USA.
e-mail: dbach{at}umich.edu
Presented at the Thirty-eighth Annual Meeting of The Society of Thoracic Surgeons, Fort Lauderdale, FL, Jan 2830, 2002.
BACKGROUND: The St. Jude Medical Regent valve is the next-generation bileaflet aortic prosthesis, modified from the currently marketed St. Jude Medical mechanical valve to achieve a larger geometric orifice without changing the existing design of the pivot mechanism or blood-contact surface areas. The present study reports the hemodynamic and early clinical results of an ongoing multicenter trial investigating the performance of the Regent valve.
METHODS: Between July 1998 and July 2001, 361 patients at 17 centers in North America and Europe underwent implantation of a Regent mechanical aortic valve prosthesis. Clinical status was prospectively recorded, and echocardiography with Doppler was performed at discharge and at 2 months, 6 months, 1 year, and 2 years after operation.
RESULTS: Follow-up to date is 300 patient-years (average, 0.8 ± 0.7 years per patient; range, 0.0 to 2.7 years). There were low rates of clinical adverse events. Mean gradient at 6 months was 9.7 ± 5.3 mm Hg, 7.6 ± 5.2 mm Hg, 6.3 ± 3.7 mm Hg, 5.8 ± 3.4 mm Hg, and 4.0 ± 2.6 mm Hg, respectively, for 19-mm, 21-mm, 23-mm, 25-mm, and 27-mm valves; effective orifice area was 1.6 ± 0.4 cm2, 2.0 ± 0.7 cm2, 2.2 ± 0.9 cm2, 2.5 ± 0.9 cm2, and 3.6 ± 1.3 cm2, respectively. Indexed effective orifice area was equal to or greater than 1.0 cm2/m2 for all valve sizes. Left ventricular mass index decreased significantly between early postoperative (165.9 ± 57.1 g/m2) and 6-month follow-up (137.9 ± 41.0 g/m2;
= -28.0 ± 49.1 g/m2; p < 0.0001).
CONCLUSIONS: The St. Jude Medical Regent aortic valve has excellent hemodynamics and early clinical results, with rapid and significant left ventricular mass regression. Long-term clinical assessment is ongoing.
This article has been cited by other articles:
![]() |
R. Guenzinger, W. B. Eichinger, I. Hettich, S. Bleiziffer, D. Ruzicka, R. Bauernschmitt, and R. Lange A prospective randomized comparison of the Medtronic Advantage Supra and St Jude Medical Regent mechanical heart valves in the aortic position: is there an additional benefit of supra-annular valve positioning? J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 462 - 471. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Emery, A. M. Emery, A. Knutsen, and G. V. Raikar Aortic Valve Replacement with a Mechanical Cardiac Valve Prosthesis Card. Surg. Adult, January 1, 2008; 3(2008): 841 - 856. [Full Text] |
||||
![]() |
P Pibarot and J G Dumesnil Prosthesis-patient mismatch: definition, clinical impact, and prevention Heart, August 1, 2006; 92(8): 1022 - 1029. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Dumesnil and P. Pibarot Prosthesis-patient mismatch and clinical outcomes: The evidence continues to accumulate J. Thorac. Cardiovasc. Surg., May 1, 2006; 131(5): 952 - 955. [Full Text] [PDF] |
||||
![]() |
J. S. Gammie, J. W. Brown, J. M. Brown, R. S. Poston, R. N. Pierson III, P. N. Odonkor, C. S. White, J. S. Gottdiener, and B. P. Griffith Aortic valve bypass for the high-risk patient with aortic stenosis. Ann. Thorac. Surg., May 1, 2006; 81(5): 1605 - 1610. [Abstract] [Full Text] [PDF] |
||||
![]() |
St Jude Medical Regent valve. J. Thorac. Cardiovasc. Surg., March 1, 2006; 131(3): 760 - 761. |
||||
![]() |
G. Tasca, Z. Mhagna, S. Perotti, P. B. Centurini, T. Sabatini, A. Amaducci, F. Brunelli, M. Cirillo, M. D. Tomba, E. Quiani, et al. Impact of Prosthesis-Patient Mismatch on Cardiac Events and Midterm Mortality After Aortic Valve Replacement in Patients With Pure Aortic Stenosis Circulation, January 31, 2006; 113(4): 570 - 576. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Otero, J. L. Pomar, J. M. Revuelta, and J. J. Rufilanchas Comparative Evaluation of Small-Size Sorin Slimline and St. Jude HP Heart Valve Prostheses Ann. Thorac. Surg., April 1, 2005; 79(4): 1284 - 1290. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Emery, C. C. Krogh, K. V. Arom, A. M. Emery, K. Benyo-Albrecht, L. D. Joyce, and D. M. Nicoloff The St. Jude Medical Cardiac Valve Prosthesis: A 25-Year Experience With Single Valve Replacement Ann. Thorac. Surg., March 1, 2005; 79(3): 776 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Amarelli, A. Della Corte, G. Romano, G. Iasevoli, G. Dialetto, L. S. De Santo, M. De Feo, M. Torella, M. Scardone, and M. Cotrufo Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 512 - 517. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Bach Choice of prosthetic heart valves:update for the next generation J. Am. Coll. Cardiol., November 19, 2003; 42(10): 1717 - 1719. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |