ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Paolo Da Col
Romeo Frassani
Rocco Carella
Ugolino Livi
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gelsomino, S.
Right arrow Articles by Livi, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gelsomino, S.
Right arrow Articles by Livi, U.

Ann Thorac Surg 2002;73:1830-1836
© 2002 The Society of Thoracic Surgeons


Original article: cardiovascular

Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: early in vivo hemodynamic results

Sandro Gelsomino, MD*a, Giorgio Morocutti, MDa, Paolo Da Col, MDa, Romeo Frassani, MDa, Rocco Carella, MDa, Giorgio Minen, MDa, Ugolino Livi, MDa

a Department of Cardiovascular Sciences, General Hospital "S. Maria Della Misericordia," Udine, Italy

Accepted for publication December 10, 2001.

* Address reprint requests to Dr Gelsomino, U. O. Cardiotoracica, Azienda Ospedaliera S. Maria Della Misericordia, Piazzale S. Maria Della Misericordia 11, 33100 Udine, Italy
e-mail: sandrogelsomino{at}virgilio.it

Background. The St. Jude Medical Regent is a new generation mechanical aortic valve.

Methods. Between March 2000 and July 2001, this valve was implanted in the aortic position in 40 patients (21 men; mean age 59.1 ± 9.0 years). Preoperatively, 24 patients (60%) were in New York Heart Association functional class III or IV. Eighteen patients (45%) underwent associated procedures. Mean valve size was 21.4 ± 2.4 mm. The mean duration of follow-up was 8.5 ± 4.5 months (range, 1 to 16 months).

Results. There were no operative deaths. Early complications included one reoperation for bleeding and one transient low output syndrome. Valve replacement was followed by a significant reduction in mean and peak transaortic gradients over time (p < 0.001) and analysis of variance failed to demonstrate statistical differences between valve size over time (p = not significant). A significant reduction in left ventricular hypertrophy occurred over time (p = 0.01) in all valve sizes (p = not significant between groups): baseline left ventricular mass index was 194 g/cm2; it reduced by 22 g/cm2 (p = 0.006) at discharge. Left ventricular mass index decreased from 172 ± 55 g/cm2 to 156 ± 44 g/cm2 (p = 0.03) from discharge to 2 months. Further reductions were not significant. Relative wall thickness decreased from 0.57 ± 0.13 preoperatively to 0.42 ± 0.06 at discharge (p = 0.001), and again at 2 months (-0.2; p = not significant), and at 1 year (-0.02; p = not significant).

Conclusions. The early experience with the St. Jude Medical Regent valve has been satisfactory.




This article has been cited by other articles:


Home page
Card Surg AdultHome page
R. W. Emery, A. M. Emery, A. Knutsen, and G. V. Raikar
Aortic Valve Replacement with a Mechanical Cardiac Valve Prosthesis
Card. Surg. Adult, January 1, 2008; 3(2008): 841 - 856.
[Full Text]


Home page
HeartHome page
R. Haaverstad, N. Vitale, A. Karevold, G. Cappabianca, A. Tromsdal, P. S. Olsen, L. Kober, H. Ihlen, K. A. Rein, and J. L Svennevig
Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study
Heart, April 1, 2007; 93(4): 500 - 505.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. Amarelli, A. Della Corte, G. Romano, G. Iasevoli, G. Dialetto, L. S. De Santo, M. De Feo, M. Torella, M. Scardone, and M. Cotrufo
Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis
J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 512 - 517.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.