ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lange, R.
Right arrow Articles by Meisner, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lange, R.
Right arrow Articles by Meisner, H.
Related Collections
Right arrow Congenital - cyanotic
Right arrow Valve disease

Ann Thorac Surg 2001;71:S365-S367
© 2001 The Society of Thoracic Surgeons


Autografts, allografts, and biological valves in children

Performance of allografts and xenografts for right ventricular outflow tract reconstruction

Ruediger Lange, MDa, Joachim Weipert, MDa, Michael Homann, MDa, Nikolaus Mendler, PhDa, Sung-Un Paek, MDa, Klaus Holper, MDa, Hans Meisner, MDa

a Department of Cardio-thoracic Surgery, German Heart Center at the Technical University, Munich, Germany

Address reprint requests to Dr Lange, Deutsches Herzzentrum München, Lazarettstr 36, 80636 München, Germany
e-mail: lange{at}dhm.mhn.de

Presented at the VIII International Symposium on Cardiac Bioprostheses, Cancun, Mexico, Nov 3–5, 2000.

Background. We compared the long-term durability of allografts and xenografts implanted for reconstruction of the right ventricular outflow tract.

Methods. A total of 401 patients were studied from January 1974 to June 2000 (145 xeno- and 256 allografts), follow-up being 98% complete. We analyzed freedom from reoperation and allograft specific factors that may indicate degeneration.

Results. The age at implantation was 2 days to 31 years (median 4.0 years). Conduit exchange rate was similar (p = 0.2) for conduit diameters less than 15 mm (41% ± 9% for allografts, 30% ± 6% for xenografts), but significantly different (p = 0.02) for diameters of 15 mm or larger (60% ± 8% for allografts, 30% ± 10% for xenografts). Diagnosis-related 20-year survival analysis showed a significantly (p = 0.01) better survival of patients with tetralogy of Fallot/pulmonary atresia (83% ± 5%) and Rastelli-type surgery (81% ± 8%) compared with patients with truncus arteriosus communis (69% ± 8%). ABO-compatibility, preservation method, and aortic or pulmonary allograft could not be identified as risk factors for allograft longevity.

Conclusions. For smaller diameters (less than 15 mm), allografts exhibit no advantage over xenografts, whereas in larger diameters (15 mm or larger) allografts are the conduit of choice for the right ventricular outflow tract.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
B. Askovich, J. A. Hawkins, C. T. Sower, L. L. Minich, L. Y. Tani, G. Stoddard, and M. D. Puchalski
Right Ventricle to Pulmonary Artery Conduit Longevity: Is it Related to Allograft Size?
Ann. Thorac. Surg., September 1, 2007; 84(3): 907 - 912.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. Horer, C. Schreiber, E. Dworak, J. Cleuziou, Z. Prodan, M. Vogt, K. Holper, and R. Lange
Long-Term Results After the Rastelli Repair for Transposition of the Great Arteries
Ann. Thorac. Surg., June 1, 2007; 83(6): 2169 - 2175.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Schreiber, R. Bauernschmitt, N. Augustin, P. Libera, R. Busley, A. Eicken, and R. Lange
Implantation of a Prosthesis Mounted Inside a Self-Expandable Stent in the Pulmonary Valvar Area Without Use of Cardiopulmonary Bypass
Ann. Thorac. Surg., January 1, 2006; 81(1): e1 - e3.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. Haas, C. Schreiber, J. Horer, M. Kostolny, K. Holper, and R. Lange
Is There a Role for Mechanical Valved Conduits in the Pulmonary Position?
Ann. Thorac. Surg., May 1, 2005; 79(5): 1662 - 1667.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Quintessenza, J. P. Jacobs, V. O. Morell, J. M. Giroud, and R. J. Boucek
Initial Experience With a Bicuspid Polytetrafluoroethylene Pulmonary Valve in 41 Children and Adults: A New Option For Right Ventricular Outflow Tract Reconstruction
Ann. Thorac. Surg., March 1, 2005; 79(3): 924 - 931.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
D. Boethig, W.-R. Thies, H. Hecker, and T. Breymann
Mid term course after pediatric right ventricular outflow tract reconstruction: a comparison of homografts, porcine xenografts and Contegras
Eur. J. Cardiothorac. Surg., January 1, 2005; 27(1): 58 - 66.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Iwai, Y. Sawa, H. Ichikawa, S. Taketani, E. Uchimura, G. Chen, M. Hara, J. Miyake, and H. Matsuda
Biodegradable polymer with collagen microsponge serves as a new bioengineered cardiovascular prosthesis
J. Thorac. Cardiovasc. Surg., September 1, 2004; 128(3): 472 - 479.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. A. Bermudez, J. A. Dearani, F. J. Puga, H. V. Schaff, C. A. Warnes, P. W. O'Leary, C. D. Schleck, and G. K. Danielson
Late results of the peel operation for replacement of failing extracardiac conduits
Ann. Thorac. Surg., March 1, 2004; 77(3): 881 - 888.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. S. Hartz, S. Y. Deleon, J. Lane, J. Dorotan, J. Joyce, E. Urbina, N. Ross-Ascuitto, and R. Ascuitto
Medtronic freestyle valves in right ventricular outflow tract reconstruction
Ann. Thorac. Surg., December 1, 2003; 76(6): 1896 - 1900.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Ishizaka, R. G. Ohye, C. S. Goldberg, S. R. Ramsburg, T. Suzuki, E. J. Devaney, and E. L. Bove
Premature failure of small-sized Shelhigh No-React porcine pulmonic valve conduit model NR-4000
Eur. J. Cardiothorac. Surg., May 1, 2003; 23(5): 715 - 718.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Cebotari, H. Mertsching, K. Kallenbach, S. Kostin, O. Repin, A. Batrinac, C. Kleczka, A. Ciubotaru, and A. Haverich
Construction of Autologous Human Heart Valves Based on an Acellular Allograft Matrix
Circulation, September 24, 2002; 106(12_suppl_1): I-63 - I-68.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. S. Allen, C. El-Zein, B. Cuneo, J. P. Cava, M. J. Barth, and M. N. Ilbawi
Pericardial tissue valves and gore-tex conduits as an alternative for right ventricular outflow tract replacement in children
Ann. Thorac. Surg., September 1, 2002; 74(3): 771 - 777.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Pearl, D. S. Cooper, K. E. Bove, and P. B. Manning
Early failure of the shelhigh pulmonary valve conduit in infants
Ann. Thorac. Surg., August 1, 2002; 74(2): 542 - 549.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. Lange, C. Schreiber, T. Gunther, M. Wottke, F. Haas, F. Meisner, J. Hess, and K. Holper
Results of biventricular repair of congenital cardiac malformations: definitive corrective surgery?
Eur. J. Cardiothorac. Surg., December 1, 2001; 20(6): 1207 - 1213.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 by The Society of Thoracic Surgeons.