Ann Thorac Surg 2001;71:S125-S132
© 2001 The Society of Thoracic Surgeons
a Cullen Cardiovascular Surgical Research Laboratories, Texas Heart Institute, Houston, Texas, USA
b Jarvik Heart, Inc, New York, New York, USA
c Oxford Heart Centre, Oxford, England, United Kingdom
Address reprint requests to Dr Frazier, Texas Heart Institute, PO Box 20345, MC 3-147, Houston, TX 77225-0345
Presented at the Fifth International Conference on Circulatory Support Devices for Severe Cardiac Failure, New York, NY, Sept 1517, 2000.
Abstract
Advances in technology and increased clinical need have led to the development of a new type of blood pump. The Jarvik 2000 Heart is an electrically powered, axial-flow left ventricular assist device that has been developed during the past 13 years. Unlike first-generation left ventricular assist devices, which were developed in the 1970s and were designed to totally capture the cardiac output, the Jarvik 2000 is designed to normalize the cardiac output by augmenting the function of the chronically failed heart for extended periods. Design iterations have been tested in 67 animals, and clinical trials have recently begun. Three patients have received the Jarvik 2000 as a bridge to transplantation, and 1 patient is being supported permanently outside the hospital. All 4 patients have improved from New York Heart Association functional class IV to class I, and 2 of them have been discharged from the hospital after heart transplantation. The experimental and clinical results indicate that the Jarvik 2000 can provide physiologic support with minimal complications and is reliable, biocompatible, and easy to implant.
This article has been cited by other articles:
![]() |
J. Haft, W. Armstrong, D. B. Dyke, K. D. Aaronson, T. M. Koelling, D. J. Farrar, and F. D. Pagani Hemodynamic and Exercise Performance With Pulsatile and Continuous-Flow Left Ventricular Assist Devices Circulation, September 11, 2007; 116(11_suppl): I-8 - I-15. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Chumnanvej, M. J. Wood, T. E. MacGillivray, and M. F. V. Melo Perioperative Echocardiographic Examination for Ventricular Assist Device Implantation Anesth. Analg., September 1, 2007; 105(3): 583 - 601. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. D. Feller, E. N. Sorensen, M. Haddad, R. N. Pierson, F. L. Johnson, J. M. Brown, and B. P. Griffith Clinical Outcomes Are Similar in Pulsatile and Nonpulsatile Left Ventricular Assist Device Recipients Ann. Thorac. Surg., March 1, 2007; 83(3): 1082 - 1088. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Clegg, D. A. Scott, E. Loveman, J. L. Colquitt, P. Royle, and J. Bryant Clinical and cost-effectiveness of left ventricular assist devices as a bridge to heart transplantation for people with end-stage heart failure: a systematic review and economic evaluation Eur. Heart J., December 2, 2006; 27(24): 2929 - 2938. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Westaby, O.H. Frazier, and A. Banning Six years of continuous mechanical circulatory support. N. Engl. J. Med., July 20, 2006; 355(3): 325 - 327. [Full Text] [PDF] |
||||
![]() |
O. H. Frazier, T. J. Myers, S. Westaby, and I. D. Gregoric Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection Ann. Thorac. Surg., January 1, 2004; 77(1): 133 - 142. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. V. Letsou, T. J. Myers, I. D. Gregoric, R. Delgado, N. Shah, K. Robertson, B. Radovancevic, and O. H. Frazier Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months Ann. Thorac. Surg., October 1, 2003; 76(4): 1167 - 1170. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. A. Nussmeier, C. B. Probert, D. Hirsch, J. R. Cooper Jr., I. D. Gregoric, T. J. Myers, and O. H. Frazier Anesthetic Management for Implantation of the Jarvik 2000TM Left Ventricular Assist System Anesth. Analg., October 1, 2003; 97(4): 964 - 971. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. J. Myers, K. Robertson, T. Pool, N. Shah, I. Gregoric, and O. H. Frazier Continuous flow pumps and total artificial hearts: management issues Ann. Thorac. Surg., June 1, 2003; 75(90060): S79 - 85. [Abstract] [Full Text] [PDF] |
||||
![]() |
O.H. Frazier Implantation of the Jarvik 2000 left ventricular assist device without the use of cardiopulmonary bypass Ann. Thorac. Surg., March 1, 2003; 75(3): 1028 - 1030. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. J. Schoen and R. F. Padera Jr. Cardiac Surgical Pathology Card. Surg. Adult, January 1, 2003; 2(2003): 119 - 185. [Full Text] |
||||
![]() |
E. L. Kukuy, M. C. Oz, and Y. Naka Long-Term Mechanical Circulatory Support Card. Surg. Adult, January 1, 2003; 2(2003): 1491 - 1506. [Full Text] |
||||
![]() |
Y. Ochiai, P. M. McCarthy, N. G. Smedira, M. K. Banbury, J. L. Navia, J. Feng, A. P. Hsu, M. L. Yeager, T. Buda, K. J. Hoercher, et al. Predictors of Severe Right Ventricular Failure After Implantable Left Ventricular Assist Device Insertion: Analysis of 245 Patients Circulation, September 24, 2002; 106(12_suppl_1): I-198 - I-202. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Westaby, O.H. Frazier, F. Beyersdorf, S. Saito, M. P. Siegenthaler, D. W. Pigott, P. A. Catarino, and R. Jarvik The Jarvik 2000 Heart. Clinical validation of the intraventricular position Eur. J. Cardiothorac. Surg., August 1, 2002; 22(2): 228 - 232. [Abstract] [Full Text] [PDF] |
||||
![]() |
F Duru, R Candinas, M Lachat, M Rahn, G Noll, T.F Luscher, and M Turina Electrical and mechanical support in advanced heart failure. Rationale and feasibility of a combined management strategy Eur. Heart J., July 1, 2002; 23(13): 1005 - 1010. [Full Text] [PDF] |
||||
![]() |
M. P. Siegenthaler, J.u. Martin, A. van de Loo, T. Doenst, W. Bothe, and F. Beyersdorf Implantation of the permanent jarvik-2000 left ventricular assist device: A single-center experience J. Am. Coll. Cardiol., June 5, 2002; 39(11): 1764 - 1772. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Westaby, A. P. Banning, S. Saito, D. W. Pigott, X. Y. Jin, P. A. Catarino, D. Robson, N. Moorjani, A. Kardos, P. A. Poole-Wilson, et al. Circulatory Support for Long-Term Treatment of Heart Failure: Experience With an Intraventricular Continuous Flow Pump Circulation, June 4, 2002; 105(22): 2588 - 2591. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. W. Duncan Mechanical circulatory support for infants and children with cardiac disease Ann. Thorac. Surg., May 1, 2002; 73(5): 1670 - 1677. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Westaby, O.H. Frazier, D. W. Pigott, S. Saito, and R. K. Jarvik Implant technique for the Jarvik 2000 heart Ann. Thorac. Surg., April 1, 2002; 73(4): 1337 - 1340. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. N. Pierson III, R. Howser, T. Donaldson, W. H. Merrill, R. J. Dignan, D. C. Drinkwater Jr, K. G. Christian, J. Butler, D. Chomsky, J. R. Wilson, et al. Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy Ann. Thorac. Surg., March 1, 2002; 73(3): 997 - 999. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |