ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Algimantas Budrikis
Richard Ingemansson
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Budrikis, A.
Right arrow Articles by Steen, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Budrikis, A.
Right arrow Articles by Steen, S.

Ann Thorac Surg 1998;66:73-78
© 1998 The Society of Thoracic Surgeons


Original articles: cardiovascular

Function of adult pig hearts after 2 and 12 hours of cold cardioplegic preservation

Algimantas Budrikis, MDa, Ramunas Bolys, MDa, Quiming Liao, MDa, Richard Ingemansson, MD, PhDa, Trygve Sjöberg, PhDa, Stig Steen, MD, PhDa

a Department of Cardiothoracic Surgery, University Hospital of Lund, Lund, Sweden

Accepted for publication February 6, 1998.

Address reprint requests to Dr Steen, Department of Cardiothoracic Surgery, University Hospital of Lund, S-221 85 Lund, Sweden

Background. Most cardioplegic solutions have been developed using the classic Langendorf heart perfusion model, which only allows a short experimental follow-up. Our aim was to investigate hearts after prolonged storage by using a physiologic model including prolonged perfusion with normal, fresh blood.

Methods. Sixteen hearts from 60-kg pigs were preserved with dextran-enriched (dextran-40, 35 g/L) St. Thomas’ solution for 2 or 12 hours after which they were continuously reperfused for 12 hours with normal blood, supplied by a support pig. A flexible balloon, fixed to an artificial valve apparatus connected to a circuit system, was inserted in the left ventricle for obtaining measurements of hemodynamic performance.

Results. During the first 3 to 4 hours of reperfusion there was no significant difference in left ventricular developed pressure, cardiac output, minute work output, or oxygen consumption between the two groups. After this time left ventricular developed pressure (p < 0.001), cardiac output (p < 0.01), minute work output (p < 0.01), and oxygen consumption were significantly lower in the 12-hour group. Coronary flow was higher (p < 0.01) and coronary vascular resistance lower (p < 0.01) during the first 5 to 6 hours of reperfusion in the 12-hour group. After 12 hours of reperfusion coronary vascular resistance was significantly higher (p < 0.01) in the 12-hour group.

Conclusions. High-degree and long-lasting coronary hyperemia at the beginning of reperfusion can be a sign of unsatisfactory preservation of the heart. This investigation shows the importance of reperfusion with normal blood and a long follow-up period after postischemic reperfusion when studying the effect of cardioplegic solutions.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
H.-J. Schafers, D. Aicher, F. Langer, and H. F. Lausberg
Preservation of the Bicuspid Aortic Valve
Ann. Thorac. Surg., February 1, 2007; 83(2): S740 - S745.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Sakamoto, K. Hashimoto, H. Okuyama, H. Takakura, S. Ishii, S. Taguchi, and H. Kagawa
Prevalence and Avoidance of Patient-Prosthesis Mismatch in Aortic Valve Replacement in Small Adults
Ann. Thorac. Surg., April 1, 2006; 81(4): 1305 - 1309.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Oshima, S. Mohri, J. Shimizu, G. Iribe, T. Imaoka, W. Fujinaka, T. Kiyooka, K. Ishino, S. Sano, F. Kajiya, et al.
Celsior Preserved Cardiac Mechanoenergetics Better Than Popular Solutions in Canine Hearts
Ann. Thorac. Surg., February 1, 2006; 81(2): 658 - 664.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. S. Bach, N. D. Kon, J. G. Dumesnil, C. F. Sintek, and D. B. Doty
Ten-Year Outcome After Aortic Valve Replacement with the Freestyle Stentless Bioprosthesis
Ann. Thorac. Surg., August 1, 2005; 80(2): 480 - 487.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. Bezon, J. N. Choplain, Y. A. Maguid, A. A. Aziz, and J. A. Barra
Failure of internal thoracic artery grafts: conclusions from coronary angiography mid-term follow-up
Ann. Thorac. Surg., September 1, 2003; 76(3): 754 - 759.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Budrikis, Q. Liao, R. Bolys, B. Westerlaken, and S. Steen
Effects of cardioplegic flushing, storage, and reperfusion on coronary circulation in the pig
Ann. Thorac. Surg., May 1, 1999; 67(5): 1345 - 1349.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 by The Society of Thoracic Surgeons.