ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Hakan Posacioglu
Yüksel Atay
Suat Buket
Ahmet Hamulu
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Posacioglu, H.
Right arrow Articles by Hamulu, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Posacioglu, H.
Right arrow Articles by Hamulu, A.

Ann Thorac Surg 1998;65:984-985
© 1998 The Society of Thoracic Surgeons

Easy Harvesting of Radial Artery With Ultrasonically Activated Scalpel

Hakan Posacioglu, MDa, Yüksel Atay, MDa, Bülent Çetindag, MDa, Osman Saribülbül, MDa, Suat Buket, MDa, Ahmet Hamulu, MDa

a Cardiovascular Surgery Department, Ege University Medical Faculty, Bornova-zmir, Turkey

Accepted for publication October 15, 1997.

Address reprint requests to Dr Hamulu, Cardiovascular Surgery Department, Ege University Medical Faculty, 35100 Bornova-zmir, Turkey

Background. The radial artery was proposed and then abandoned as a coronary artery bypass graft in the 1970s. Development of new pharmacologic antispasmodic agents and minimally traumatic harvesting techniques has led to a revival of the use of the radial artery in coronary artery bypass surgery. Usually the main reasons for the spasm are thermal injury caused by electrocautery and traumatic harvesting technique.

Methods. In our technique an ultrasonically activated scalpel (Harmonic Scalpel; Ultracision Inc, Smithfield, RI) was used for radial artery harvesting without using hemostatic clips for vessel side branches. The patients in the study were divided into two groups of 10 patients each. In the first group radial arteries were harvested with this technique, and in the second group with hemostatic clips, scissors, and minimal electrocautery. Harvesting time, frequency of spasm, and use of hemostatic clips were compared between the two groups.

Results. The Harmonic Scalpel decreased the harvesting time, frequency of spasm, and excessive use of hemostatic clips.

Conclusions. Good coagulation capacity with markedly decreased use of hemostatic clips and minimized thermal injury offers the surgeon the ability to perform less traumatic, spasm free, and rapid radial artery harvesting.