ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Ken Suzuki
Yoshiki Sawa
Toshiki Takahashi
Hajime Ichikawa
Hikaru Matsuda
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suzuki, K.
Right arrow Articles by Matsuda, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suzuki, K.
Right arrow Articles by Matsuda, H.

Ann Thorac Surg 1998;65:54-58
© 1998 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Early Detection of Cardiac Damage With Heart Fatty Acid-Binding Protein After Cardiac Operations

Ken Suzuki, MD, Yoshiki Sawa, MD, Keishi Kadoba, MD, Toshiki Takahashi, MD, Hajime Ichikawa, MD, Koji Kagisaki, MD, Toshihiro Ohata, MD, Hikaru Matsuda, MD

First Department of Surgery, Osaka University, Osaka, Japan

Accepted for publication October 3, 1997.

Dr Suzuki, First Department of Surgery, Osaka University Medical School, 2-2 Yamada-Oka, Suita, Osaka, 565, Japan.

Background. It is still difficult to evaluate myocardial damage in the acute phase of reperfusion in cardiac operations. We investigated the clinical significance of human heart fatty acid-binding protein (HH-FABP) for detecting myocardial damage after cardiac operations earlier than creatine kinase MB isoform or troponin-T.

Methods. Blood samples from 20 patients who underwent coronary artery bypass grafting were collected serially after reperfusion to measure serum levels of creatine kinase-MB, troponin-T, and HH-FABP.

Results. Serum HH-FABP levels peaked earliest after reperfusion. In addition, the maximum serum HH-FABP level was predictable immediately after reperfusion. The maximum serum HH-FABP level correlated with the maximum serum creatine kinase-MB or troponin-T level, as well as with the aortic cross-clamp time or the maximum dose of catecholamines administered after reperfusion.

Conclusions. Measurements of HH-FABP allow for earlier evaluation of myocardial damage in the acute phase of reperfusion. Human heart fatty acid-binding protein may be a useful indicator of myocardial damage after cardiac operations.