ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Tomio Abe
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fukada, J.
Right arrow Articles by Abe, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fukada, J.
Right arrow Articles by Abe, T.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 1997;64:1678-1680
© 1997 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Influence of Pulmonic Position on Durability of Bioprosthetic Heart Valves

Johji Fukada, MD, Kiyohumi Morishita, MD, PhD, Kanshi Komatsu, MD, PhD, Tomio Abe, MD, PhD

Department of Thoracic and Cardiovascular Surgery, Sapporo Medical University School of Medicine, Sapporo, Japan

Accepted for publication May 8, 1997.

Background. The insertion of bioprosthetic valves into the pulmonic position is not performed commonly because of uncertainty concerning the necessity and durability of such valves.

Methods. We reviewed the long-term outcome of 10 patients who underwent pulmonary valve replacement with bioprostheses between March 1985 and March 1997. A Carpentier-Edwards supraannular bioprosthesis was used in 7 patients, a Hancock II bioprosthesis was used in 2 patients, and a Carpentier-Edwards pericardial bioprosthesis was used in 1 patient. The mean patient age at the time of pulmonary valve replacement was 38.9 ± 16.3 years (range, 15 to 63 years). The diagnoses were pulmonary valvular regurgitation after corrective surgery for tetralogy of Fallot in 7 patients, right ventricular outflow tract stenosis and absent right pulmonary artery combined with a double-outlet right ventricle in 1 patient, pulmonary valvular regurgitation with pulmonary artery dilatation in 1 patient, and aortic valve stenosis treated with our modification of the Ross procedure using a pulmonary bioprosthesis in 1 patient. Survivors were followed up for a mean of 5 years and 5 months.

Results. One patient underwent reoperation because of infective endocarditis of the bioprosthesis. No bioprosthetic valve dysfunction has been observed on Doppler echocardiography during a maximum follow-up period of 12.2 years, except in the patient who underwent replacement at 15 years of age.

Conclusions. Bioprostheses in the pulmonic position are durable in adult patients because they face a minimal hemodynamic load, but they may undergo early leaflet degeneration in younger patients.


Related Article

Invited Commentary
Carl L. Backer
Ann. Thorac. Surg. 1997 64: 1680-1681. [Extract] [Full Text]






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 by The Society of Thoracic Surgeons.