ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Harold L. Lazar
Gabriel S. Aldea
Richard J. Shemin
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lazar, H. L.
Right arrow Articles by Shemin, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lazar, H. L.
Right arrow Articles by Shemin, R. J.

Ann Thorac Surg 1997;63:1701-1705
© 1997 The Society of Thoracic Surgeons


Original Article: Cardiovascular

Heparin-Bonded Circuits Decrease Myocardial Ischemic Damage: An Experimental Study

Harold L. Lazar, MD, Xi Zhang, MD, PhD, Takafumi Hamasaki, MD, Ciriaco A. Memmelo, MD, Patrick Treanor, CCP, Samuel Rivers, BS, Gabriel S. Aldea, MD, Sheilah A. Bernard, MD, Richard J. Shemin, MD

Department of Cardiothoracic Surgery, The Boston University Medical Center, Boston, Massachusetts

Accepted for publication December 23, 1996.

Background. Heparin-bonded cardiopulmonary bypass circuits reduce complement activation, but their effect on myocardial function is unknown. This study was undertaken to determine whether heparin-bonded circuits reduce myocardial damage during acute surgical revascularization.

Methods. In 16 pigs, the second and third diagonal vessels were occluded with snares for 90 minutes followed by 45 minutes of cardioplegic arrest and 180 minutes of reperfusion with the snares released. During the period of coronary occlusion, all animals were placed on percutaneous bypass followed by standard cardiopulmonary bypass during the periods of cardioplegic arrest and reperfusion. In 8 pigs, heparin-bonded circuits were used, whereas 8 other pigs received nonbonded circuits.

Results. Animals treated with heparin-bonded circuits had the best preservation of wall motion scores (3.5 ± 0.3 versus 2.3 ± 0.2; 4 = normal to -1 = dyskinesis; p < 0.05), least tissue acidosis (change in pH = -0.31 ± 0.02 versus -0.64 ± 0.08; p < 0.05), smallest increase in lung H2O (1.7% ± 0.7% versus 6.1% ± .5%; p < 0.05), and the lowest area of necrosis/area of risk (20.3% ± 2.2% versus 40.4% ± 1.6%; p < 0.05).

Conclusions. We conclude that heparin-bonded circuits significantly decrease myocardial ischemic damage during acute surgical revascularization.




This article has been cited by other articles:


Home page
CirculationHome page
H. L. Lazar, P. M. Bokesch, F. van Lenta, C. Fitzgerald, C. Emmett, H. C. Marsh Jr, U. Ryan, and OBE and the TP10 Cardiac Surgery Study Group
Soluble Human Complement Receptor 1 Limits Ischemic Damage in Cardiac Surgery Patients at High Risk Requiring Cardiopulmonary Bypass
Circulation, September 14, 2004; 110(11_suppl_1): II-274 - II-279.
[Abstract] [Full Text] [PDF]


Home page
Journal of Bioactive and Compatible PolymersHome page
U. Demirkilic, E. Kuralay, H. Tatar, M. Kocakulak, C. Kocum, and H. Ayhan
Investigation of Blood Compatibility and Determination of Clinical Performance of PMEA Coated and Flow Optimized Oxygenator
Journal of Bioactive and Compatible Polymers, September 1, 2004; 19(5): 395 - 408.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Ikuta, H. Fujii, T. Shibata, K. Hattori, H. Hirai, H. Kumano, and S. Suehiro
A new poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit possesses superior platelet preservation and inflammatory suppression efficacy
Ann. Thorac. Surg., May 1, 2004; 77(5): 1678 - 1683.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
H. I Flom-Halvorsen, E Ovrum, F Brosstad, G Tangen, M A. Ringdal, and R Oystese
Effects of two differently heparin-coated extracorporeal circuits on markers for brain and myocardial dysfunction
Perfusion, September 1, 2002; 17(5): 339 - 345.
[Abstract] [PDF]


Home page
PerfusionHome page
L.-C. Hsu
Heparin-coated cardiopulmonary bypass circuits: current status
Perfusion, September 1, 2001; 16(5): 417 - 428.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Suhara, Y. Sawa, M. Nishimura, H. Oshiyama, K. Yokoyama, N. Saito, and H. Matsuda
Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model
Ann. Thorac. Surg., May 1, 2001; 71(5): 1603 - 1608.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. Belboul, C. Lofgren, C. Storm, and M. Jungbeck
Heparin-coated circuits reduce occult myocardial damage during CPB: a randomized, single blind clinical trial
Eur. J. Cardiothorac. Surg., May 1, 2000; 17(5): 580 - 586.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Wan, J.-L. LeClerc, M. Antoine, J.-M. DeSmet, A. P.C. Yim, and J.-L. Vincent
Heparin-coated circuits reduce myocardial injury in heart or heart-lung transplantation: a prospective, randomized study
Ann. Thorac. Surg., October 1, 1999; 68(4): 1230 - 1235.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. L. Lazar, Y. Bao, J. Gaudiani, S. Rivers, and H. Marsh
Total Complement Inhibition : An Effective Strategy to Limit Ischemic Injury During Coronary Revascularization on Cardiopulmonary Bypass
Circulation, September 28, 1999; 100(13): 1438 - 1442.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, C. Volpe, Y. Bao, S. Rivers, J. A. Vita, and J. F. Keaney Jr
Beneficial effects of angiotensin-converting enzyme inhibitors during acute revascularization
Ann. Thorac. Surg., August 1, 1998; 66(2): 487 - 492.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, T. Hamasaki, Y. Bao, S. Rivers, S. A. Bernard, and R. J. Shemin
Soluble Complement Receptor Type I Limits Damage During Revascularization of Ischemic Myocardium
Ann. Thorac. Surg., April 1, 1998; 65(4): 973 - 977.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 by The Society of Thoracic Surgeons.