ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Correction (v64,p892)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nomori, H.
Right arrow Articles by Horio, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nomori, H.
Right arrow Articles by Horio, H.

Ann Thorac Surg 1997;63:352-355
© 1997 The Society of Thoracic Surgeons


Original Article: General Thoracic

Gelatin-Resorcinol-Formaldehyde-Glutaraldehyde Glue-Spread Stapler Prevents Air Leakage From the Lung

Hiroaki Nomori, MD, Hirotoshi Horio, MD

Department of Surgery, Saiseikai Central Hospital, Tokyo, Japan

Accepted for publication September 12, 1996.

Background. To reinforce the staple line of the emphysematous lung and thereby prevent air leakage during thoracoscopic operations, we have developed a procedure of lung excision that uses a gelatin-resorcinol-formaldehyde-glutaraldehyde (GRFG) glue-spread stapler.

Methods. Formaldehyde-glutaraldehyde (FG) jelly is prepared by mixing FG fluid with 2.5% sodium carboxymethyl cellulose. The FG jelly is placed in the stapler groove and staple holes, and a gelatin-resorcinol (GR) mixture is applied. The GRFG glue-spread stapler was applied to emphysematous lung cutting during thoracoscopic operations in 10 cases.

Results. An adhesion-strength test showed no difference in glue adhesion between FG fluid and FG jelly. An experiment using swine lung showed that with this newly developed stapler, no resistance in firing occurred, and GRFG glue covered every staple hole. Clinical application in 10 cases with emphysematous lung demonstrated no air leakage from the staple line, even long after the operation.

Conclusions. Emphysematous lung excision using the GRFG glue-spread stapler during thoracoscopic operations is useful in preventing air leakage from the staple line and is a simple, safe, and low-cost procedure.




This article has been cited by other articles:


Home page
The Annals of PharmacotherapyHome page
K. S Lewis, S. L Kane-Gill, M. B. Bobek, and J. F Dasta
Intensive Insulin Therapy for Critically Ill Patients
Ann. Pharmacother., July 1, 2004; 38(7): 1243 - 1251.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. W. Hewitt, S. W. Marra, B. R. Kann, H. S. Tran, M. M. Puc, F. A. Chrzanowski Jr, J.-L. V. Tran, S. D. Lenz, J. H. Cilley Jr, V. A. Simonetti, et al.
BioGlue surgical adhesive for thoracic aortic repair during coagulopathy: efficacy and histopathology
Ann. Thorac. Surg., May 1, 2001; 71(5): 1609 - 1612.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. L. Porte, T. Jany, R. Akkad, M. Conti, P. A. Gillet, A. Guidat, and A. J. Wurtz
Randomized controlled trial of a synthetic sealant for preventing alveolar air leaks after lobectomy
Ann. Thorac. Surg., May 1, 2001; 71(5): 1618 - 1622.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Nomori, H. Horio, and K. Suemasu
Mixing collagen with fibrin glue to strengthen the sealing effect for pulmonary air leakage
Ann. Thorac. Surg., November 1, 2000; 70(5): 1666 - 1670.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
B. A. Feito, A. M. Rath, E. Longchampt, and J. Azorin
Experimental study on the in vivo behaviour of a new collagen glue in lung surgery
Eur. J. Cardiothorac. Surg., January 1, 2000; 17(1): 8 - 13.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Aoki and S. Kaseda
Thoracoscopic resection of the lung with the ultrasonic scalpel
Ann. Thorac. Surg., April 1, 1999; 67(4): 1181 - 1183.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Nomori, H. Horio, S. Morinaga, and K. Suemasu
Gelatin-resorcinol-formaldehyde-glutaraldehyde glue for sealing pulmonary air leaks during thoracoscopic operation
Ann. Thorac. Surg., January 1, 1999; 67(1): 212 - 216.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 by The Society of Thoracic Surgeons.