Ann Thorac Surg 1996;62:1617-1621
© 1996 The Society of Thoracic Surgeons
Thoracic and Cardiovascular Research Laboratory, Department of Surgery, University of Virginia Health Sciences Center, Charlottesville, Virginia
Accepted for publication June 27, 1996.
Background. Decreased airway compliance after lung transplantation has been observed with severe ischemia-reperfusion injury. Further, it has been shown that the surfactant system is impaired after lung preservation and reperfusion. We hypothesized that surfactant replacement after allograft storage could preserve airway compliance during reperfusion.
Methods. Rabbit lungs were harvested after flush with 50 mL/kg of cold saline solution. Immediate control lungs were studied with an isolated ventilation/perfusion apparatus using venous rabbit blood recirculated at 40 mL/min, room-air ventilation at 20 breaths/min, and constant airway pressure (n = 8). Twenty-fourhour control lungs were preserved at 4°C for 24 hours and then similarly studied (n = 7). Surfactant lungs underwent similar harvest and preservation for 24 hours, but received 1.5 mL/kg of intratracheal surfactant 5 minutes before reperfusion (n = 10). Airway pressure and flow were recorded continuously during 30 minutes of reperfusion. Tidal volume and airway compliance were calculated at 30 minutes.
Results. Tidal volume was 33.67 ± 0.57, 15.75 ± 5.72, and 29.83 ± 1.07 mL in the immediate control, 24-hour control, and surfactant groups, respectively (p = 0.004, surfactant versus 24-hour control). Airway compliance was 1.94 ± 0.27, 0.70 ± 0.09, and 1.46 ± 0.10 mL/mm Hg in the immediate control, 24-hour control, and surfactant groups, respectively (p = 0.002, surfactant versus 24-hour control).
Conclusions. We conclude that surfactant administration before reperfusion after 24 hours of cold storage preserves tidal volume and airway compliance in the isolated ventilated/perfused rabbit model of lung reperfusion injury.
This article has been cited by other articles:
![]() |
M. de Perrot, M. Liu, T. K. Waddell, and S. Keshavjee Ischemia-Reperfusion-induced Lung Injury Am. J. Respir. Crit. Care Med., February 15, 2003; 167(4): 490 - 511. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. N. Ghadiali, J. Banks, and J. D. Swarts Effect of surface tension and surfactant administration on Eustachian tube mechanics J Appl Physiol, September 1, 2002; 93(3): 1007 - 1014. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Mathias, C. G. Tribble, J. F. Dietz, R. P. Nguyen, K. S. Shockey, J. A. Kern, and I. L. Kron Aprotinin improves pulmonary function during reperfusion in an isolated lung model Ann. Thorac. Surg., November 1, 2000; 70(5): 1671 - 1674. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Itano, M. Aoe, S. Ichiba, M. Yamashita, H. Date, A. Andou, and N. Shimizu Partial liquid ventilation for acute allograft dysfunction after canine lung transplantation Ann. Thorac. Surg., February 1, 1999; 67(2): 332 - 339. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |