ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Thierry Beyens
Jacques P. Goldstein
Frank E. Deuvaert
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bové, T.
Right arrow Articles by Deuvaert, F. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bové, T.
Right arrow Articles by Deuvaert, F. E.

Ann Thorac Surg 1996;62:1347-1350
© 1996 The Society of Thoracic Surgeons


Original Article: Cardiovascular

Nonvalved Homografts of Thoracic Aorta in Operation for Complex Congenital Cardiac Disease

Thierry Bové, MD, Hélène Demanet, MD, Thierry Beyens, MD, Pierre Viart, MD, Hugue Dessy, MD, Andrée Deville, MD, Jacques P. Goldstein, PhD, Frank E. Deuvaert, MD

Cardiac Unit, Hôpital Universitaire des Enfants Reine Fabiola, Brussels, Belgium

Accepted for publication May 24, 1996.

Background. In contrast to the wide and successful use of valved aortic and pulmonary homografts, the nonvalved prolongation of the thoracic aorta for the repair of some complex congenital heart diseases has rarely been described. We present here our experience with the use of descending aorta and aortic arch homografts as nonvalved conduits for the surgical repair of complex cardiac malformations in 8 patients.

Methods. One atriopulmonary conduit replacement, four extraatrial cavopulmonary connections, and one intraatrial cavopulmonary repair were achieved by means of a homograft of the descending aorta with a diameter of 15 to 17 mm. Three pulmonary unifocalization procedures were carried out in 2 more patients using a curved homograft of the aortic arch with a diameter of 18 mm. Except for 1 patient, whose incompetent common atrioventricular valve was replaced with a mechanical prosthesis, all other patients were managed without anticoagulation.

Results. No conduit-related complications were seen during a follow-up of 18 to 42 months. One patient died perioperatively during an emergency central repair of the right ventricular outflow tract after bilateral unifocalization with arch homografts. Another patient died suddenly 4 months after cavopulmonary connection. The remaining 6 patients are currently doing well.

Conclusions. Regardless of the complexity of the underlying malformations, we are encouraged to use nonvalved thoracic aortic homografts in the repair of congenital cardiac diseases because of the reduction in thrombotic, hemorrhagic, and infectious complications associated with their use; convenience in handling; and their versatility in size and shape.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.