ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jeffrey E. Everett
Sara J. Shumway
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Everett, J. E.
Right arrow Articles by Shumway, S. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Everett, J. E.
Right arrow Articles by Shumway, S. J.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 1996;62:1337-1340
© 1996 The Society of Thoracic Surgeons


Original Article: Cardiovascular

Noninvasive Diagnosis of Cardiac Allograft Rejection in an Orthotopic Canine Model

Jeffrey E. Everett, MD, Mitchell N. Palmer, BS, Jose Jessurun, MD, Sara J. Shumway, MD

Division of Cardiovascular and Thoracic Surgery, Department of Surgery, and Department of Pathology, University of Minnesota, Minneapolis, Minnesota

Accepted for publication May 13, 1996.

Background. A decline in the R wave voltage obtained from surface electrocardiograms once correlated with cardiac allograft rejection. With cyclosporine therapy, however, these electrocardiographic findings became inconsistent, occurring only during severe rejection episodes. Despite cyclosporine use, intramyocardial unipolar peak-to-peak amplitudes obtained from plunge electrodes are reported to be highly sensitive and specific for diagnosing rejection. These reports are based on heterotopic grafts, which atrophy over time, making long-term voltage changes during rejection difficult to interpret. The purpose of this study was to use analysis of unipolar peak-to-peak amplitudes as a prospective monitoring tool for diagnosing orthotopic cardiac allograft rejection.

Methods. Ten adult mongrel dogs underwent orthotopic heart transplantation with the attachment of four intramyocardial leads. The unipolar peak-to-peak amplitudes were measured daily and compared with endomyocardial biopsy results.

Results. We found that intramyocardial unipolar peak-to-peak amplitude analysis had a sensitivity and a specificity of 100% for diagnosing rejection. We also found that as the number of myocardial leads increased, the sensitivity of detecting rejection also increased.

Conclusions. We conclude that unipolar peak-to-peak amplitude analysis is an accurate noninvasive means for early detection of cardiac allograft rejection in an orthotopic model. Its success should allow less frequent, more selective use of endomyocardial biopsy.


Related Article

Invited Commentary
Johannes Müller and Roland Hetzer
Ann. Thorac. Surg. 1996 62: 1340-1341. [Extract] [Full Text]



This article has been cited by other articles:


Home page
CirculationHome page
D. C. Morgan, J. E. Wilson, C. E. MacAulay, N. B. MacKinnon, J. A. Kenyon, P. S. Gerla, C. Dong, H. Zeng, P. D. Whitehead, C. R. Thompson, et al.
New Method for Detection of Heart Allograft Rejection : Validation of Sensitivity and Reliability in a Rat Heterotopic Allograft Model
Circulation, September 14, 1999; 100(11): 1236 - 1241.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.