ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Noriyoshi Sawabata
Takashi Tojo
Soichiro Kitamura
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sawabata, N.
Right arrow Articles by Kitamura, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sawabata, N.
Right arrow Articles by Kitamura, S.

Ann Thorac Surg 1996;61:164-169
© 1996 The Society of Thoracic Surgeons


Original Articles: General Thoracic

In Vitro Study of Ablated Lung Tissue in Nd:YAG Laser Irradiation

Noriyoshi Sawabata, MD, Kunimoto Nezu, MD, Takashi Tojo, MD, Soichiro Kitamura, MD

Department of Surgery III, Nara Medical College, Nara, Japan

Accepted for publication August 15, 1995.

Background. Neodymium:yttrium-aluminum garnet lasers are used to reduce lung volume. An assessment of the relationship between the histologic and gross findings in the lung irradiated by a laser would be helpful in laser-assisted pneumoplastic procedures.

Methods. In vitro lung lobes surgically resected for pulmonary carcinomas were irradiated with a neodymium:yttrium-aluminum garnet laser at three energy levels in three modes: contact rubbing, contact pointing, and noncontact. Pleural degeneration in 216 samples from 24 lobes was classified as coagulative, amorphous, or destructive. At all energy levels, the laser was applied for 1.5 seconds.

Results. Noncontact mode at 7.5 W or 15 W and contact rubbing at 5 W caused coagulative or amorphous degeneration but no destructive degeneration. The energy level correlated with the color of the degenerated pleura. The incidence of destructive pleural degeneration, which led to air leaks as revealed by an air inflation test, was 0% in pink and white samples, 59% in brown samples, and 100% in black samples (p < 0.0001, white versus brown samples).

Conclusions. In neodymium:yttrium-aluminum garnet laser ablation of lung tissue, the color of the degenerated pleura correlates with the intensity of the applied laser energy and the degree of pleural degeneration.




This article has been cited by other articles:


Home page
ChestHome page
N. Sawabata, M. Ikeda, A. Matsumura, H. Maeda, S. Miyoshi, and H. Matsuda
New Electroablation Technique Following the First-Line Stapling Method for Thoracoscopic Treatment of Primary Spontaneous Pneumothorax
Chest, January 1, 2002; 121(1): 251 - 255.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.