ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Bart P. Meyns
Paul T. Sergeant
Willem J. Flameng
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyns, B. P.
Right arrow Articles by Flameng, W. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyns, B. P.
Right arrow Articles by Flameng, W. J.

Ann Thorac Surg 1995;60:392-397
© 1995 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Left Ventricular Assistance With the Transthoracic 24F Hemopump for Recovery of the Failing Heart

Bart P. Meyns, MD, Paul T. Sergeant, MD, Wim J. Daenen, MD, Willem J. Flameng, MD

Department of Cardiac Surgery, Gasthuisberg University Hospital, Leuven, Belgium

Accepted for publication April 4, 1995.

Background. The Hemopump was developed as a more powerful assist device for postcardiotomy support in patients in whom the intraaortic balloon pump is insufficient.

Methods. Over a 2-year period 21 (0.8%) of 2,585 patients undergoing cardiac operations needed a ventricular assist device because of postcardiotomy heart failure unresponsive to pharmacologic and intraaortic balloon support. Sixteen of these patients were assisted with the 24F transthoracic Hemopump left ventricular assist device. The aim of the mechanical support was myocardial recovery as the underlying conditions (age, arterial hypertension, diabetes, vascular and pulmonary disease) excluded heart transplantation.

Results. Hemodynamic improvement was apparent with a decrease in left atrial pressure (mean, 18.6 to 9.2 mm Hg), an increase in arterial blood pressure (mean, 54.1 to 70.1 mm Hg), and an increase in cardiac index. Five patients died within the first 24 hours because of low cardiac output. Although the heart was well unloaded (decrease in left atrial pressure of 8 ± 4.69 mm Hg versus 9.3 ± 5.51 mm Hg for the other patients), the increase in cardiac index was significantly lower (+0.516 versus +1.377 L • min-1 • m-2; p = 0.027). Three of these 5 patients were known to have severe left ventricular hypertrophy. Of the remaining 11 patients, 2 were assisted for 1 week but failed to show recovery of the myocardium, 8 (50%) were weaned, and 4 (25%) were discharged. There were no device-related complications except the thrombosis of a cannula that was left for 10 days.

Conclusions. The transthoracic Hemopump is an easy-to-use and reliable assist device. Left ventricular hypertrophy is a relative contraindication for the use of the Hemopump.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
A. R. Davies, R. Bellomo, J. S. Raman, G. A. Gutteridge, and B. F. Buxton
High lactate predicts the failure of intraaortic balloon pumping after cardiac surgery
Ann. Thorac. Surg., May 1, 2001; 71(5): 1415 - 1420.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. P. Meyns, Y. Nishimura, R. Jashari, R. Racz, V. H. Leunens, and W. J. Flameng
Ascending versus descending aortic balloon: Pumping: organ and myocardial perfusion during ischemia
Ann. Thorac. Surg., October 1, 2000; 70(4): 1264 - 1269.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. Meyns, P. Sergeant, P. Wouters, F. Casselman, P. Herijgers, W. Daenen, K. Bogaerts, and W. Flameng
Mechanical support with microaxial blood pumps for postcardiotomy left ventricular failure: Can outcome be predicted?
J. Thorac. Cardiovasc. Surg., August 1, 2000; 120(2): 393 - 400.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
B. Meyns, P. Sergeant, T. Nishida, B. Perek, M. Zietkiewicz, and W. Flameng
Micropumps to support the heart during CABG
Eur. J. Cardiothorac. Surg., February 1, 2000; 17(2): 169 - 174.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
B Meyns, S Ozaki, P Sergeant, Y Nishimura, and W Flameng
Circulatory support during minimally invasive coronary surgery
Perfusion, July 1, 1998; 13(4): 265 - 271.
[PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
N. G. Smedira, C. C. Hlozek, and P. M. McCarthy
Mechanical Support After Cardiac Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1998; 2(1): 66 - 77.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. Meyns, Y. Nishimura, R. Racz, R. Jashari, and W. Flameng
ORGAN PERFUSION WITH HEMOPUMP DEVICE ASSISTANCE WITH AND WITHOUT INTRAAORTIC BALLOON PUMPING
J. Thorac. Cardiovasc. Surg., August 1, 1997; 114(2): 243 - 253.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
B. Peterzen, U. Lonn, A. Babic, H. Granfeldt, H. Casimir-Ahn, and H. Rutberg
Postoperative Management of Patients With Hemopump Support After Coronary Artery Bypass Grafting
Ann. Thorac. Surg., August 1, 1996; 62(2): 495 - 500.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
B. P. Meyns, P. T. Sergeant, W. J. Daenen, and W. J. Flameng
Invited Commentary
Ann. Thorac. Surg., August 1, 1996; 62(2): 500 - 500.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1995 by The Society of Thoracic Surgeons.