Ann Thorac Surg 1995;59:389-392
© 1995 The Society of Thoracic Surgeons
Section of Cardiothoracic Surgery, William S. Middleton Memorial Veterans Hospital, University of Wisconsin School of Medicine, Madison, Wisconsin
Accepted for publication September 21, 1994.
In an effort to develop a noninvasive method to evaluate flow characteristics of the internal thoracic artery (ITA) graft after coronary artery bypass grafting, we performed color-flow duplex ultrasound studies of the right and left ITAs of 42 patients before and 5 weeks after bypass grafting. The ITA was visualized with a duplex scanner (5.0-MHz probe) through the first or second intercostal space. We recorded the diameter, peak systolic velocity, and end-diastolic velocity for each patient. Preoperative measurements of the native ITAs were obtained easily in all patients. Postoperatively, the unused right ITA was seen in all patients. Postoperative visualization of the left ITA graft was adequate to make reliable measurements in 40 patients (95%). Postoperative end-diastolic velocities of the unused right ITA and the left ITA graft were markedly higher than the preoperative end-diastolic velocities of the native ITAs (p < 0.001). Whereas there was a marked increase in the peak systolic velocity of the postoperative unused right ITA (p < 0.05), the postoperative peak systolic velocity of the left ITA graft was significantly lower than the preoperative value (p < 0.001). We conclude that postoperative visualization of the left ITA graft is possible with the use of color-flow duplex ultrasound. Ultrasonic surveillance of postoperative ITAs may reveal ITA graft velocity abnormalities before overt graft failure is manifested in the patient who has undergone coronary artery bypass grafting.
This article has been cited by other articles:
![]() |
R. Marx, G. Kalweit, U. Sunderdiek, T. W. Jax, R. M. Klein, S. Szabo, H. M. Hoffmeister, and H. Gulker Stress Doppler echocardiography of the internal thoracic artery - a new non-invasive approach for functional assessment after minimally invasive coronary bypass grafting Interactive CardioVascular and Thoracic Surgery, October 1, 2006; 5(5): 584 - 588. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Yoshitatsu, Y. Miyamoto, M. Mitsuno, K. Toda, M. Yoshikawa, S. Fukui, F. Nomura, N. Hirata, and K. Onishi Changes in left anterior descending coronary artery flow profiles after coronary artery bypass grafting examined by means of transthoracic Doppler echocardiography J. Thorac. Cardiovasc. Surg., November 1, 2003; 126(5): 1531 - 1536. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Prifti, M. Bonacchi, G. Frati, P. Proietti, G. Giunti, and M. Leacche {lambda}graft with the radial artery or free left internal mammary artery anastomosed to the right internal mammary artery: flow dynamics Ann. Thorac. Surg., October 1, 2001; 72(4): 1275 - 1281. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Tavilla, N. H.J. Pijls, E. Berreklouw, and K. H. Peels Noninvasive assessment of right gastroepiploic artery graft patency using transcutaneous color Doppler echocardiography Ann. Thorac. Surg., March 1, 1999; 67(3): 624 - 628. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Gaudino, M. Serricchio, F. Glieca, P. Bruno, P. Tondi, A. Giordano, C. Trani, M. L. Calcagni, P. Pola, and G. Possati Steal phenomenon from mammary side branches: when does it occur? Ann. Thorac. Surg., December 1, 1998; 66(6): 2056 - 2062. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. C. Canver, V. M. Armstrong, S. D. Cooler, and R. D. Nichols Assessment of Internal Thoracic Artery Vasoreactivity in Response to Sublingual Nitroglycerin Ann. Thorac. Surg., April 1, 1997; 63(4): 1041 - 1043. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |