ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gol, M. K.
Right arrow Articles by Bayazit, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gol, M. K.
Right arrow Articles by Bayazit, K.

The Annals of Thoracic Surgery, Vol 58, 1476-1480, Copyright © 1994 by The Society of Thoracic Surgeons


ARTICLES

Vascular complications related to percutaneous insertion of intraaortic balloon pumps

MK Gol, M Bayazit, M Emir, O Tasdemir and K Bayazit
Cardiovascular Surgery Department, Turkiye Yuksek Ihtisas Hospital, Ankara.

The hemodynamic effects of intraaortic balloon pumps (IABPs) are well known. The use of IABPs is prone to many complications, including those classified as vascular. These complications are said to be more frequent with percutaneous insertion techniques. These complications and the algorithm for identifying patients who are most likely to suffer vascular complications were evaluated in a retrospective manner in a group of patients that received percutaneous IABPs. The study group consisted of 449 patients. The mean age of these patients was 53.6 +/- 12.8 years (range, 18 to 80 years), and 24.7% were female. The early mortality rate of these patients was 53.2%. The mortality for patients in whom vascular complications developed was significantly higher than that in the patients who did not suffer any vascular complications (65.7% versus 50.8%; p = 0.018). Minor or major vascular complications developed in 17.4% (n = 78) of the patients. There was no statistical difference in the frequency of complications between the patients who received a sheathless IABP and those who received a sheathed IABP. Ischemic complications occurred in 16.6% of the patients who received a sheathless IABP and in 17.6% of the patients with sheathed IABPs (p < 0.05). Diabetic patients (relative risk, 2.5), female patients (relative risk, 1.83), patients with peripheral vascular disease (relative risk, 3.69), and patients undergoing coronary artery bypass operations (relative risk, 2.08) were at increased risk for suffering vascular complications. These risk factors should be evaluated before insertion of an IABP, and routes other than percutaneous femoral insertion are preferred if the patient is IABP dependent.


This article has been cited by other articles:


Home page
ICVTSHome page
I. Norkiene, D. Ringaitiene, K. Rucinskas, R. Samalavicius, A. Baublys, S. Miniauskas, and V. Sirvydis
Intra-aortic balloon counterpulsation in decompensated cardiomyopathy patients: bridge to transplantation or assist device
Interactive CardioVascular and Thoracic Surgery, February 1, 2007; 6(1): 66 - 70.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
I. R. Ramnarine, A. D. Grayson, W. C. Dihmis, N. K. Mediratta, B. M. Fabri, and J. A.C. Chalmers
Timing of intra-aortic balloon pump support and 1-year survival
Eur. J. Cardiothorac. Surg., May 1, 2005; 27(5): 887 - 892.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. J. F. Baskett, G. T. O'Connor, G. M. Hirsch, W. A. Ghali, K. Sabadosa, J. R. Morton, C. S. Ross, F. Hernandez, W. C. Nugent Jr, S. J. Lahey, et al.
A multicenter comparison of intraaortic balloon pump utilization in isolated coronary artery bypass graft surgery
Ann. Thorac. Surg., December 1, 2003; 76(6): 1988 - 1992.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
R. Salenger, J. S. Gammie, and T. J. Vander Salm
Postoperative Care of Cardiac Surgical Patients
Card. Surg. Adult, January 1, 2003; 2(2003): 439 - 469.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
R. J.F. Baskett, W. A. Ghali, A. Maitland, and G. M. Hirsch
The intraaortic balloon pump in cardiac surgery
Ann. Thorac. Surg., October 1, 2002; 74(4): 1276 - 1287.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
Z. S. Meharwal and N. Trehan
Vascular complications of intra-aortic balloon insertion in patients undergoing coronary reavscularization: analysis of 911 cases
Eur. J. Cardiothorac. Surg., April 1, 2002; 21(4): 741 - 747.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. J. Ferguson III, M. Cohen, R. J. Freedman Jr, G. W. Stone, M. F. Miller, D. L. Joseph, and E. M. Ohman
The current practice of intra-aortic balloon counterpulsation: results from the Benchmark Registry
J. Am. Coll. Cardiol., November 1, 2001; 38(5): 1456 - 1462.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Chavanon, V. Dutheil, R. Hacini, E. Borrel, F. Tremel, and D. Blin
TREATMENT OF SEVERE CARDIAC CONTUSION WITH A LEFT VENTRICULAR ASSIST DEVICE IN A PATIENT WITH MULTIPLE TRAUMA
J. Thorac. Cardiovasc. Surg., July 1, 1999; 118(1): 189 - 190.
[Full Text] [PDF]


Home page
ANGIOLOGYHome page
S. Deniz Kumbasar, E. Semiz, O. Sancaktar, S. Yalcinkaya, C. Ermis, and N. Deger
Concomitant Use of Intraaortic Balloon Counterpulsation and Streptokinase in Acute Anterior Myocardial Infarction
Angiology, June 1, 1999; 50(6): 465 - 471.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1994 by The Society of Thoracic Surgeons.