ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Menasche, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Menasche, P.

The Annals of Thoracic Surgery, Vol 58, 533-535, Copyright © 1994 by The Society of Thoracic Surgeons


ARTICLES

Experimental comparison of manually inflatable versus autoinflatable retrograde cardioplegia catheters

P Menasche
Department of Cardiovascular Surgery, Hopital Lariboisiere, Paris, France.

A pig model of cardiopulmonary bypass and cardioplegic arrest was used to compare leakage around manually inflatable and autoinflatable retrograde coronary sinus cardioplegia catheters. Warm and cold blood cardioplegia were alternately delivered through the catheter under study at both low (16 to 24 mm Hg) and high (30 to 40 mm Hg) perfusion pressures. During each experiment, the coronary sinus ostium was sealed around the shaft of the retrograde cannula so that all backflow occurring during cardioplegia delivery could be collected by a separate drainage catheter inserted directly into the coronary sinus approximately midway between the right atrium and the distal end of the balloon. Only two of the 52 manually inflatable cannulas leaked. The leakage in both cases was negligible (< 1% of the total retrograde cardioplegia flow). In contrast, leakage occurred with 57 of the 73 autoinflatable devices tested (p < 0.0001) and averaged 22% +/- 3% (mean +/- the standard error of the mean) of the total retrograde flow. The temperature of the cardioplegia solution had no effect on leakage. These results suggest that autoinflatable balloons inconsistently seal the coronary sinus during cardioplegia infusion, thereby decreasing the amount of flow that effectively reaches the myocardium. This should make surgeons cautious about using them with warm blood cardioplegia, which largely relies upon the delivery of sufficiently high retrograde nutritive flows for preventing cardioprotective aerobic arrest from becoming a life-threatening ischemic arrest.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
Z.-K. Wu, M. R. Tarkka, E. Pehkonen, L. Kaukinen, E. L. Honkonen, and S. Kaukinen
Beneficial effects of ischemic preconditioning on right ventricular function after coronary artery bypass grafting
Ann. Thorac. Surg., November 1, 2000; 70(5): 1551 - 1557.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
V. Rao, G. Cohen, R. D. Weisel, N. Shiono, Y. Nonami, S. M. Carson, J. Ivanov, M. A. Borger, R. J. Cusimano, and D. A. Mickle
Optimal flow rates for integrated cardioplegia
J. Thorac. Cardiovasc. Surg., January 1, 1998; 115(1): 226 - 230.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. E. Cimochowski, M. D. Harostock, and P. J. Foldes
MINIMAL OPERATIVE MORTALITY IN PATIENTS UNDERGOING CORONARY ARTERY BYPASS WITH SIGNIFICANT LEFT VENTRICULAR DYSFUNCTION BY MAXIMIZATION OF METABOLIC AND MECHANICAL SUPPORT
J. Thorac. Cardiovasc. Surg., April 1, 1997; 113(4): 655 - 666.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1994 by The Society of Thoracic Surgeons.