ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pillai, R.
Right arrow Articles by Westaby, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pillai, R.
Right arrow Articles by Westaby, S.

The Annals of Thoracic Surgery, Vol 56, 88-90, Copyright © 1993 by The Society of Thoracic Surgeons


ARTICLES

Stentless aortic bioprosthesis? The way forward: early experience with the Edwards valve

R Pillai, D Spriggings, N Amarasena, DJ O'Regan, AJ Parry and S Westaby
Department of Cardiac Surgery, Oxford Heart Centre, John Radcliffe Hospital, Oxford, United Kingdom.

Tissue valve degeneration has been variably attributed to preservation and fixation methods. Additionally, a rigid valve ring might contribute to valve failure. The use of a nonstented porcine valve in the aortic position has clear hemodynamic advantages, and the lack of a stent may favorably influence long-term function. We have implanted stentless aortic valves (Prima valve) in 31 patients. There were 17 men. The mean age was 71.5 years (range, 50 to 83 years). After sculpturing of the sinuses the valve is positioned below the coronary arteries. Valve sizes ranged from 19 to 27 mm. There were no early or late deaths. Mean follow-up to date is 8.9 months (range, 4 weeks to 15 months). Early hemodynamic follow-up using Doppler echocardiography shows average peak systolic and mean gradients of 20.4 mm Hg and 8.6 mm Hg, respectively, at 4 weeks in 26 patients, with no significant change in 13 patients at 6 months. All patients are currently in New York Heart Association class I or II. Our early experience of stentless aortic valves shows them to be reliable with a satisfactory early hemodynamic profile. Their use in the elderly may conserve homografts for children and the young.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. Kattach, X. Jin, S. Mussa, and R. Pillai
Regurgitation through a stentless prosthesis treated with aortic root banding
J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 672 - 673.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
U. Bortolotti, G. Scioti, A. Milano, G. Borzoni, C. Nardi, and G. Tartarini
The Edwards Prima stentless valve: hemodynamic performance at one year
Ann. Thorac. Surg., December 1, 1999; 68(6): 2147 - 2151.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Gross, W. Harringer, H. Beran, R. Mair, K. Sihorsch, R. Hofmann, and P. Brucke
Aortic valve replacement: is the stentless xenograft an alternative to the homograft? midterm results
Ann. Thorac. Surg., September 1, 1999; 68(3): 919 - 924.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
X. Y. Jin, R. Pillai, and S. Westaby
Medium-term determinants of left ventricular mass index after stentless aortic valve replacement
Ann. Thorac. Surg., February 1, 1999; 67(2): 411 - 416.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
X. Y. Jin, K. Dhital, K. Bhattacharya, R. Pieris, N. Amarasena, and R. Pillai
Fifth-year hemodynamic performance of the prima stentless aortic valve
Ann. Thorac. Surg., September 1, 1998; 66(3): 805 - 809.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. F. Del Rizzo, B. S. Goldman, G. T. Christakis, and T. E. David
HEMODYNAMIC BENEFITS OF THE TORONTO STENTLESS VALVE
J. Thorac. Cardiovasc. Surg., December 1, 1996; 112(6): 1431 - 1446.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
S. Westaby, N. Amarasena, V. Long, A. Prothero, G. A. C. Amarasena, A. P. Banning, R. Pillai, and O. Ormerod
Time-Related Hemodynamic Changes After Aortic Replacement With the Freestyle Stentless Xenograft
Ann. Thorac. Surg., December 1, 1995; 60(6): 1633 - 1638.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
N. D. Kon, S. Westaby, N. Amarasena, R. Pillai, and A. R. Cordell
Comparison of Implantation Techniques Using Freestyle Stentless Porcine Aortic Valve
Ann. Thorac. Surg., April 1, 1995; 59(4): 857 - 862.
[Abstract] [Full Text]