ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gorton, M. E.
Right arrow Articles by Borkon, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gorton, M. E.
Right arrow Articles by Borkon, A. M.

The Annals of Thoracic Surgery, Vol 55, 860-863, Copyright © 1993 by The Society of Thoracic Surgeons


ARTICLES

Mitral valve repair using a flexible and adjustable annuloplasty ring

ME Gorton, JM Piehler, DA Killen, ML Hoskins and AM Borkon
Mid America Heart Institute, St. Luke's Hospital, Kansas City, Missouri.

Initial experience with a new flexible and adjustable mitral annuloplasty ring is described. Used in conjunction with standard techniques of mitral valve repair, this ring was implanted in 21 consecutive patients undergoing elective operation for mitral regurgitation. Satisfactory valve repair was feasible in 20 of these patients. Once the ring was sewn in place, adjustment of the ring to reduce or eliminate residual regurgitation was beneficial in 9 patients. Excellent results were achieved as determined by intraoperative transesophageal echocardiography. Comparable late results were found in all but 1 patient up to 1 year after repair. This patient required mitral valve replacement 6 months after repair due to failure of papillary muscle reconstruction. The BiFlex ring has the merits of a flexible prosthesis with the advantage of easy adjustment once secured in place.


This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
M. Arita, S. Tono, H. Kasegawa, and M. Umezu
Multiple Purpose Simulator Using a Natural Porcine Mitral Valve
Asian Cardiovasc Thorac Ann, December 1, 2004; 12(4): 350 - 356.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
A. M. Gillinov and D. M. Cosgrove III
Mitral Valve Repair
Card. Surg. Adult, January 1, 2003; 2(2003): 933 - 950.
[Full Text]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
M. Arita, H. Kasegawa, and M. Umezu
Development of In-Vitro Evaluation System for Annuloplasty Rings
Asian Cardiovasc Thorac Ann, March 1, 2001; 9(1): 14 - 18.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
V. Borghetti, M. Campana, C. Scotti, D. Domenighini, P. Totaro, G. Coletti, M. Pagani, and R. Lorusso
Biological versus prosthetic ring in mitral-valve repair: enhancement of mitral annulus dynamics and left-ventricular function with pericardial annuloplasty at long term
Eur. J. Cardiothorac. Surg., April 1, 2000; 17(4): 431 - 439.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Kawahira, T. Yagihara, H. Uemura, T. Ishizaka, K. Yoshizumi, and S. Kitamura
Use of expanded polytetrafluoroethylene sutures as artificial tendinous cords in children with congenital mitral regurgitation
Eur. J. Cardiothorac. Surg., March 1, 1999; 15(3): 289 - 293.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Dall'Agata, M. A. Taams, P. M. Fioretti, J. R. T. C. Roelandt, and L. A. Van Herwerden
Cosgrove-Edwards Mitral Ring Dynamics Measured With Transesophageal Three-Dimensional Echocardiography
Ann. Thorac. Surg., February 1, 1998; 65(2): 485 - 490.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Scrofani, S. Moriggia, M. Salati, P. Fundaro, P. Danna, and C. Santoli
Mitral Valve Remodeling: Long-Term Results With Posterior Pericardial Annuloplasty
Ann. Thorac. Surg., March 1, 1996; 61(3): 895 - 899.
[Abstract] [Full Text]


Home page
CirculationHome page
J. A. Odell, H. V. Schaff, and T. A. Orszulak
Early Results of a Simplified Method of Mitral Valve Annuloplasty
Circulation, November 1, 1995; 92(9): 150 - 154.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
T. E. David
Update on Mitral Valve Repair
Ann. Thorac. Surg., May 1, 1995; 59(5): 1257 - 1258.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1993 by The Society of Thoracic Surgeons.