ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Videm, V.
Right arrow Articles by Svennevig, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Videm, V.
Right arrow Articles by Svennevig, J. L.

The Annals of Thoracic Surgery, Vol 54, 725-731, Copyright © 1992 by The Society of Thoracic Surgeons


ARTICLES

Time for new concepts about measurement of complement activation by cardiopulmonary bypass?

V Videm, E Fosse, TE Mollnes, P Garred and JL Svennevig
Institute for Experimental Medical Research, Ullevaal Hospital, Oslo, Norway.

Fifty-one patients admitted for routine coronary bypass operations were randomized to cardiopulmonary bypass with a membrane oxygenator (Capiox) or a bubbler (Polystan or William Harvey). Complement activation was measured using enzyme immunoassays for concentrations of C3 activation products and the terminal complement complex. From 5.8 to 8.1 arbitrary units (AU)/mL (medians), the plasma concentrations of C3 activation products increased by 119.9 AU/mL (Capiox), 124.6 AU/mL (Polystan), and 79.5 AU/mL (William Harvey) to a peak at closure of the sternum (not significant when related to baseline concentrations). The increase in C3 activation products and baseline C3 activation were linearly correlated (R2 = 0.30; p less than 0.0001). From 5.5 to 6.1 AU/mL, the plasma terminal complement complex concentrations increased by 45.2 AU/mL (Capiox), 15.4 AU/mL (Polystan), and 17.4 AU/mL (William Harvey) to a peak before termination of cardiopulmonary bypass. Maximal terminal (C5-C9) activation was significantly higher in the membrane oxygenator group (p less than 0.0001) and showed no relationship to C3 activation. Measurement of C3 activation only gives no information about C5-C9 activation. At present, terminal complement complex quantitation is probably the best index of C5-C9 activation during cardiopulmonary bypass.


This article has been cited by other articles:


Home page
PerfusionHome page
K Svennevig, T. Hoel, A. Thiara, S. Kolset, A Castelheim, T. Mollnes, F Brosstad, E Fosse, and J. Svennevig
Syndecan-1 plasma levels during coronary artery bypass surgery with and without cardiopulmonary bypass
Perfusion, May 1, 2008; 23(3): 165 - 171.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
I. Risnes, T. Ueland, P. Aukrust, R. Lundblad, S. T. Baksaas, T. E. Mollnes, and J. L. Svennevig
Complement activation and cytokine and chemokines release during mediastinitis
Ann. Thorac. Surg., March 1, 2003; 75(3): 981 - 985.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
H. A. Hennein
Inflammation After Cardiopulmonary Bypass: Therapy for the Postpump Syndrome
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2001; 5(3): 236 - 255.
[Abstract] [PDF]


Home page
PerfusionHome page
G Matheis, M Scholz, J Gerber, U Abdel-Rahman, G Wimmer-Greinecker, and A Moritz
Leukocyte filtration in the early reperfusion phase on cardiopulmonary bypass reduces myocardial injury
Perfusion, January 1, 2001; 16(1): 43 - 49.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. L. Korn, C. A. Fisher, E. R. Livingston, N. Stenach, S. J. Fishman, V. Jeevanandam, and V. P. Addonizio
THE EFFECTS OF CARMEDA BIOACTIVE SURFACE ON HUMAN BLOOD COMPONENTS DURING SIMULATED EXTRACORPOREAL CIRCULATION
J. Thorac. Cardiovasc. Surg., May 1, 1996; 111(5): 1073 - 1084.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Finn, B. P. Morgan, N. Rebuck, N. Klein, C. A. Rogers, M. Hibbs, M. Elliott, D. F. Shore, T. W. Evans, S. Strobel, et al.
EFFECTS OF INHIBITION OF COMPLEMENT ACTIVATION USING RECOMBINANT SOLUBLE COMPLEMENT RECEPTOR 1 ON NEUTROPHIL CD11B/CD18 AND L-SELECTIN EXPRESSION AND RELEASE OF INTERLEUKIN-8 AND ELASTASE IN SIMULATED CARDIOPULMONARY BYPASS
J. Thorac. Cardiovasc. Surg., February 1, 1996; 111(2): 451 - 459.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. de Haan, P. W. Boonstra, N. Tabuchi, W. van Oeveren, and T. Ebels
RETRANSFUSION OF THORACIC WOUND BLOOD DURING HEART SURGERY OBSCURES BIOCOMPATIBILITY OF THE EXTRACORPOREAL CIRCUIT
J. Thorac. Cardiovasc. Surg., January 1, 1996; 111(1): 272 - 275.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
O. Moen, E. Fosse, V. Brockmeier, C. Andersson, T. E. Mollnes, K. Hogasen, and P. Venge
Disparity in Blood Activation by Two Different Heparin-Coated Cardiopulmonary Bypass Systems
Ann. Thorac. Surg., November 1, 1995; 60(5): 1317 - 1323.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. Gonzalez, T. Morrissey, T. Byrne, R. Rizzo, and D. Wilmore
Bioelectric impedance detects fluid retention in patients undergoing cardipulmonary bypass
J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 111 - 118.
[Abstract] [Full Text]


Home page
PerfusionHome page
Z. A Varga
Autologous plateletpheresis in cardiac surgery
Perfusion, November 1, 1993; 8(6): 471 - 476.
[Abstract] [PDF]


Home page
PerfusionHome page
V. Videm, E. Fosse, and J. L Svennevig
Platelet preservation during coronary bypass surgery with bubble and membrane oxygenators: effect of albumin priming
Perfusion, September 1, 1993; 8(5): 409 - 415.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The Society of Thoracic Surgeons.