ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Curtis, J. J.
Right arrow Articles by Flaker, G. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Curtis, J. J.
Right arrow Articles by Flaker, G. C.

The Annals of Thoracic Surgery, Vol 53, 984-987, Copyright © 1992 by The Society of Thoracic Surgeons


ARTICLES

Time to first pulse after automatic implantable cardioverter defibrillator implantation

JJ Curtis, JT Walls, TM Boley, HE Stephenson, RA Schmaltz, W Nawarawong and GC Flaker
Division of Cardiothoracic Surgery, University of Missouri, Columbia 65212.

Should automatic implantable cardioverter defibrillator (AICD) power sources be explanted and discontinued if they have not pulsed during the first generator life? We have followed 59 patients an average of 23 months (range, 3 days to 8.4 years) after AICD implantation. The indication for AICD implantation was based on clinical dysrhythmia, history of sudden death, and findings at electrophysiologic study. Thirty-eight of 59 patients (64%) had experienced sudden death and 52/58 (90%) were inducible at electrophysiologic study. Excluding 5 inappropriate pulsing episodes, 31 of 59 patients (53%) had 235 pulses (range, 1 to 36; median, 2 pulses). The time to first pulse after implantation ranged from 1 day to 3.5 years with a median time of 2 months. In 6 patients, the first pulsing occurred later than 1 year after AICD implantation. Fifteen generators demonstrating impending power source failure have been replaced in 11 patients. Power source depletion occurred at an average of 24.1 months (range, 8 to 40 months). In 3 patients, the first pulsing occurred after generator depletion and replacement. By univariate analysis, none of 13 variables (sex, age, cardiac disease process, functional class, previous myocardial infarction, sudden death history, ejection fraction, type of dysrhythmia, inducibility with electrophysiologic testing, number of extra stimuli required for induction, left ventricular aneurysm resection, endocardial resection, or concomitant operation) was found to be a predictor of pulsing (p greater than 0.05). We conclude that the majority of patients with pulses after AICD implantation will have them during the first 6 months.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
A. E. Epstein, W. M. Miles, D. G. Benditt, A. J. Camm, E. J. Darling, P. L. Friedman, A. Garson, J. C. Harvey, G. A. Kidwell, G. J. Klein, et al.
Personal and Public Safety Issues Related to Arrhythmias That May Affect Consciousness: Implications for Regulation and Physician Recommendations: A Medical/Scientific Statement From the American Heart Association and the North American Society of Pacing and Electrophysiology
Circulation, September 1, 1996; 94(5): 1147 - 1166.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The Society of Thoracic Surgeons.