ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heerdt, P. M.
Right arrow Articles by Rosenbloom, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heerdt, P. M.
Right arrow Articles by Rosenbloom, M.

The Annals of Thoracic Surgery, Vol 53, 706-708, Copyright © 1992 by The Society of Thoracic Surgeons


ARTICLES

Inaccuracy of cardiac output by thermodilution during acute tricuspid regurgitation

PM Heerdt, CG Pond, GA Blessios and M Rosenbloom
Division of Cardiothoracic Anesthesiology, Washington University School of Medicine, St. Louis, MO 63110.

We have been comparing cardiac output measured with a novel Doppler pulmonary artery catheter to that measured by thermodilution and aortic electromagnetometry in cardiac surgical patients. We report here our observation of a nearly twofold increase in thermodilution cardiac output after the acute intraoperative onset of tricuspid regurgitation that was not confirmed by the novel catheter or direct measurement of aortic blood flow. We conclude that in some patients, acute tricuspid regurgitation may lessen the reliability of thermodilution cardiac output.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
C. W. Buffington and E. U. M. Nystrom
Neither the Accuracy nor the Precision of Thermal Dilution Cardiac Output Measurements Is Altered by Acute Tricuspid Regurgitation in Pigs
Anesth. Analg., April 1, 2004; 98(4): 884 - 890.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. M. HOEPER, R. MAIER, J. TONGERS, J. NIEDERMEYER, J. M. HOHLFELD, M. HAMM, and H. FABEL
Determination of Cardiac Output by the Fick Method, Thermodilution, and Acetylene Rebreathing in Pulmonary Hypertension
Am. J. Respir. Crit. Care Med., August 1, 1999; 160(2): 535 - 541.
[Abstract] [Full Text]


Home page
PerfusionHome page
E. A Hessel II
Review article : What's new in monitoring the coronary surgery patient?
Perfusion, July 1, 1992; 7(3): 161 - 194.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The Society of Thoracic Surgeons.