ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Delius, R. E.
Right arrow Articles by Bartlett, R. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Delius, R. E.
Right arrow Articles by Bartlett, R. H.

The Annals of Thoracic Surgery, Vol 53, 278-281, Copyright © 1992 by The Society of Thoracic Surgeons


ARTICLES

New method for describing the performance of cardiac surgery cannulas

RE Delius, JP Montoya, SI Merz, J McKenzie, S Snedecor, EL Bove and RH Bartlett
Department of Surgery, University of Michigan Medical Center, Ann Arbor 49109-0331.

Cardiac surgery cannulas are characterized by external diameter only, which provides little information about the pressure-flow characteristics of a cannula. A system has been developed to describe pressure-flow characteristics with a single, unitless number, M, which is patterned after a Reynolds friction factor correlation. A cannula with a lower M number has a more favorable pressure-flow relationship. The M number was determined for 16 arterials cannulas ranging in size from 10F to 26F and 27 venous cannulas sized 12F to 36F. Pressure-flow characteristics vary considerably among cannulas from different manufacturers despite having similar French sizes. Clinical decisions regarding choice of cannula can be simplified by using the M number, which gives a more accurate description of the performance characteristics of a cannula than the French size designation.


This article has been cited by other articles:


Home page
PerfusionHome page
D. Jegger, S. Sundaram, K. Shah, I. Mallabiabarrena, G. Mucciolo, and L.K. von Segesser
Using computational fluid dynamics to evaluate a novel venous cannula (Smart canula (R)) for use in cardiopulmonary bypass operating procedures
Perfusion, July 1, 2007; 22(4): 257 - 265.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Kurusz, D. J Deyo, A. D Sholar, W. Tao, and J. B Zwischenberger
Laboratory testing of femoral venous cannulae: effect of size, position and negative pressure on flow
Perfusion, September 1, 1999; 14(5): 379 - 387.
[Abstract] [PDF]


Home page
PerfusionHome page
K. McCusker, D. Hoffman, W. Maldarelli, S. Toplitz, and D. Sisto
High-flow femoro-femoral bypass utilizing small cannulae and a centrifugal pump on the venous side
Perfusion, October 1, 1992; 7(4): 295 - 300.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The Society of Thoracic Surgeons.