ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Downing, S. W.
Right arrow Articles by Edmunds, L. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Downing, S. W.
Right arrow Articles by Edmunds, L. H., Jr

The Annals of Thoracic Surgery, Vol 53, 132-138, Copyright © 1992 by The Society of Thoracic Surgeons


ARTICLES

Left ventricular assistance without thoracotomy: mediastinal and transseptal approaches to the left heart

SW Downing, M Llaneras, D Georgi, DC Wood, EB Savage and LH Edmunds Jr
Department of Surgery, University of Pennsylvania School of Medicine, Philadelphia.

Two methods to cannulate the left atrium for initiating mechanical left ventricular circulatory assistance using a centrifugal pump were investigated in 25 sheep. A modified Dennis transatrial septal approach produced flow rates of 88.6 +/- 14 mL.kg-1.min-1 through 21F catheters inserted during fluoroscopy through the jugular vein. In 8 animals the septal perforation was plugged after decannulation with a modified Rashkind umbrella plug. Fibroendothelial tissue covered the plug by 4 week. In 7 other animals, the septal defect was not plugged. The septal defect reached pinpoint size by 2 weeks and was completely closed by 4 weeks. In 10 sheep, the left atrium was cannulated from the neck through the mediastinum. Left ventricular assistance flow averaged 71.6 +/- 14 mL.kg-1.min-1. Mean blood loss during 1 hour of left ventricular assistance was 47 mL. In 8 animals, the atrial perforation was plugged with a mean blood loss of 253 +/- 194 mL. In 2 animals, the perforation was intentionally not plugged; mean blood loss was 700 mL. All animals survived. The modified Dennis transatrial method is recommended as a safe, expeditious, cost-effective method to implement left ventricular assistance without thoracotomy. The mediastinal approach, which is technically possible in humans, is more difficult but feasible. Left ventricular assistance has been proven to be the most effective way to rest the failing, ejecting left ventricle. Implementation without thoracotomy potentially expands applications of left ventricular assistance for temporary support of patients with severe manifestations of ischemic heart disease.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
M. Yano, T. Onitsuka, K. Shibata, and Y. Koga
Efficacy and Safety of a Percutaneous Right Ventricular Assist System