ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ovrum, E.
Right arrow Articles by Oystese, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ovrum, E.
Right arrow Articles by Oystese, R.

The Annals of Thoracic Surgery, Vol 52, 500-505, Copyright © 1991 by The Society of Thoracic Surgeons


ARTICLES

Conventional blood conservation techniques in 500 consecutive coronary artery bypass operations

E Ovrum, EA Holen, M Abdelnoor and R Oystese
Oslo Heart Center, Norway.

With use of a nonpharmacological, simple, and inexpensive program for blood conservation, 500 consecutive patients underwent elective coronary artery bypass grafting without need of homologous red cell transfusions in 493 (98.6%). At least one internal mammary artery was grafted in all but 1 patient, with supplemental saphenous vein grafts. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of extracorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard- shell cardiotomy reservoir from the heart-lung machine, autotransfusion of the shed mediastinal blood was continued hourly up to 18 hours after operation. The mean postoperative mediastinal blood loss was 643 +/- 354 mL, whereas 624 +/- 296 mL was autotransfused. Thirteen patients (2.6%) needed reexploration for bleeding, of whom 7 (7/500, 1.4%) received homologous blood. No other patients required red cell transfusions. In addition, 9 patients were given a mean of 2.6 units of fresh frozen plasma because of suspected coagulopathy. No platelets were transfused, and no cryoprecipitate therapy was undertaken. Thus, in total, 484 patients (96.8%) were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 121 +/- 14 g/L (12.1 +/- 1.4 g/dL) and the hematocrit, 0.36 +/- 0.04. Postoperative complications were few. There was one in-hospital death (0.2%).


This article has been cited by other articles:


Home page
PerfusionHome page
E. Sirvinskas, A. Veikutiene, R. Benetis, P. Grybauskas, J. Andrejaitiene, V. Veikutis, and J. Surkus
Influence of early re-infusion of autologous shed mediastinal blood on clinical outcome after cardiac surgery
Perfusion, September 1, 2007; 22(5): 345 - 352.
[Abstract] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
A. Shander, D. Moskowitz, and T. S. Rijhwani
The Safety and Efficacy of "Bloodless" Cardiac Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2005; 9(1): 53 - 63.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. I. Flom-Halvorsen, E. Ovrum, R. Oystese, and F. Brosstad
Quality of intraoperative autologous blood withdrawal used for retransfusion after cardiopulmonary bypass
Ann. Thorac. Surg., September 1, 2003; 76(3): 744 - 748.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
S J Morris
Leukocyte reduction in cardiovascular surgery
Perfusion, September 1, 2001; 16(5): 371 - 380.
[PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. I. Flom-Halvorsen, E. Ovrum, G. Tangen, F. Brosstad, M.-A. L. Ringdal, and R. Oystese
AUTOTRANSFUSION IN CORONARY ARTERY BYPASS GRAFTING: DISPARITY IN LABORATORY TESTS AND CLINICAL PERFORMANCE
J. Thorac. Cardiovasc. Surg., October 1, 1999; 118(4): 610 - 617.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
S. T Baksaas, H. I Flom-Halvorsen, E. Ovrum, V. Videm, T. E. Mollnes, F. Brosstad, and J. L Svennevig
Leucocyte filtration during cardiopulmonary reperfusion in coronary artery bypass surgery
Perfusion, March 1, 1999; 14(2): 107 - 117.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
U. Lonn, B. Peterzen, B. Carnstam, and H. Casimir-Ahn
Beating heart coronary surgery supported by an axial blood flow pump
Ann. Thorac. Surg., January 1, 1999; 67(1): 99 - 104.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. N. D'Ambra, R. J. Gray, R. Hillman, J. W. Jones, H. C. Kim, R. Rawitscher, H. Schnaper, I. Szymanski, G. J. Vlahakes, D. Kaplan, et al.
Effect of Recombinant Human Erythropoietin on Transfusion Risk in Coronary Bypass Patients
Ann. Thorac. Surg., December 1, 1997; 64(6): 1686 - 1693.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
G. S. Kochamba, T. A. Pfeffer, C. F. Sintek, and S. Khonsari
Intraoperative Autotransfusion Reduces Blood Loss After Cardiopulmonary Bypass
Ann. Thorac. Surg., March 1, 1996; 61(3): 900 - 903.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, T. E. Mollnes, E. Fosse, E. A. Holen, G. Tangen, M.-A. L. Ringdal, and V. Videm
High and Low Heparin Dose With Heparin-Coated Cardiopulmonary Bypass: Activation of Complement and Granulocytes
Ann. Thorac. Surg., December 1, 1995; 60(6): 1755 - 1761.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. Ovrum, T. E. Mollnes, E. Fosse, E. A. Holen, G. Tangen, M. Abdelnoor, M.-A. L. Ringdal, R. Oystese, and P. Venge
COMPLEMENT AND GRANULOCYTE ACTIVATION IN TWO DIFFERENT TYPES OF HEPARINIZED EXTRACORPOREAL CIRCUITS
J. Thorac. Cardiovasc. Surg., December 1, 1995; 110(6): 1623 - 1632.
[Abstract] [Full Text]


Home page
CirculationHome page
E. Ovrum, F. Brosstad, E. Am Holen, G. Tangen, and M. Abdelnoor
Effects on Coagulation and Fibrinolysis With Reduced Versus Full Systemic Heparinization and Heparin-Coated Cardiopulmonary Bypass
Circulation, November 1, 1995; 92(9): 2579 - 2584.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, E. A. Holen, G. Tangen, F. Brosstad, M. Abdelnoor, M.-A. L. Ringdal, R. Oystese, and R. Istad
Completely Heparinized Cardiopulmonary Bypass and Reduced Systemic Heparin: Clinical and Hemostatic Effects
Ann. Thorac. Surg., August 1, 1995; 60(2): 365 - 371.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. R. Jobes, G. L. Aitken, and G. W. Shaffer
Increased accuracy and precision of heparin and protamine dosing reduces blood loss and transfusion patients undergoing primary cardiac operations
J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 36 - 45.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. Ovrum and M. Abdelnoor
Tranexamic acid after bypass: Too late to help?
J. Thorac. Cardiovasc. Surg., May 1, 1994; 107(5): 1376 - 1377.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1991 by The Society of Thoracic Surgeons.