ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ross, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ross, D.

The Annals of Thoracic Surgery, Vol 52, 154-156, Copyright © 1991 by The Society of Thoracic Surgeons


ARTICLES

Technique of aortic valve replacement with a homograft: orthotopic replacement

D Ross
Harley Street Clinic, London, England.

Homograft replacement of the aortic valve has become increasingly popular. The technique of insertion is essentially simple but a number of variations have developed over the years. The valve can be inserted in orthotopic (subcoronary) position or as a root replacement. The technique described here has developed over the past 28 years and links up with the related operation of pulmonary valve translocation (pulmonary autograft).


This article has been cited by other articles:


Home page
Eur Heart JHome page
L. M.A. Klieverik, J. A. Bekkers, J. W. Roos, M.J.C. Eijkemans, G. B. Raap, Ad. J.J.C. Bogers, and J. J.M. Takkenberg
Autograft or allograft aortic valve replacement in young adult patients with congenital aortic valve disease
Eur. Heart J., June 1, 2008; 29(11): 1446 - 1453.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. J.M. Takkenberg, L. M.A. Klieverik, J. A. Bekkers, A. P. Kappetein, J. W. Roos, M. J.C. Eijkemans, and A. J.J.C. Bogers
Allografts for aortic valve or root replacement: insights from an 18-year single-center prospective follow-up study
Eur. J. Cardiothorac. Surg., May 1, 2007; 31(5): 851 - 859.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Talwar, R. Mohapatra, A. Saxena, R. Singh, and A. S. Kumar
Aortic Homograft: A Suitable Substitute for Aortic Valve Replacement
Ann. Thorac. Surg., September 1, 2005; 80(3): 832 - 838.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. M. Dohmen, A. Lembcke, H. Hotz, D. Kivelitz, and W. F. Konertz
Ross operation with a tissue-engineered heart valve
Ann. Thorac. Surg., November 1, 2002; 74(5): 1438 - 1442.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J.J.M. Takkenberg, L.A. van Herwerden, M.J.C. Eijkemans, J.A. Bekkers, and A.J.J.C. Bogers
Evolution of allograft aortic valve replacement over 13 years: results of 275 procedures
Eur. J. Cardiothorac. Surg., April 1, 2002; 21(4): 683 - 691.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. P. Willems, J. J. M. Takkenberg, E. W. Steyerberg, V. E. Kleyburg-Linkers, J. R. T. C. Roelandt, E. Bos, and L. A. van Herwerden
Human Tissue Valves in Aortic Position : Determinants of Reoperation and Valve Regurgitation
Circulation, March 20, 2001; 103(11): 1515 - 1521.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
D. N Ross
Choice of Valves -- Homografts
Asian Cardiovasc Thorac Ann, December 1, 2000; 8(4): 303 - 304.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. K. Choudhary, A. Saxena, B. Dubey, and A. S. Kumar
Pulmonary homograftShould it be used in the aortic position?
J. Thorac. Cardiovasc. Surg., July 1, 2000; 120(1): 148 - 155.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. P. Willems, L. A. Van Herwerden, M. A. Taams, V. E. Kleyburg-Linker, J. R.T.C. Roelandt, and E. Bos
Aortic allograft implantation techniques: pathomorphology and regurgitant jet patterns by doppler echocardiographic studies
Ann. Thorac. Surg., August 1, 1998; 66(2): 412 - 416.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. R. Doty, J. D. Salazar, J. R. Liddicoat, J. H. Flores, and D. B. Doty
Aortic Valve Replacement With Cryopreserved Aortic Allograft: Ten-Year Experience
J. Thorac. Cardiovasc. Surg., February 1, 1998; 115(2): 371 - 380.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. L. Jones, V. B. Shah, J. S. Shanewise, T. D. Martin, R. P. Martin, J. A. Coto, R. Broniec, and Y. Shen
Should the Freehand Allograft Be Abandoned as a Reliable Alternative for Aortic Valve Replacement?
Ann. Thorac. Surg., June 1, 1995; 59(6): 1397 - 1403.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1991 by The Society of Thoracic Surgeons.