ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Antunes, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Antunes, M. J.

The Annals of Thoracic Surgery, Vol 50, 743-747, Copyright © 1990 by The Society of Thoracic Surgeons


ARTICLES

Clinical performance of St. Jude and Medtronic-Hall prostheses: a randomized comparative study

MJ Antunes
Division of Cardiothoracic Surgery, University of the Witwatersrand, Johannesburg, South Africa.

Newer and improved models of mechanical prostheses are regularly added to surgeons' armamentarium. This study was designed to compare the clinical performance of two of the most used current models of mechanical prostheses. From August 1983 through July 1985, 182 white patients were prospectively randomized to implantation of the St. Jude Medical (95 patients) or Medtronic-Hall (87 patients) prostheses. There were 84 mitral, 85 aortic, and 13 double (mitral and aortic) valve replacements. There were no differences between the two groups with regard to sex distribution, age, functional class, emergency operation, and site of implantation. Early mortality was 3.2% for patients with the St. Jude valve and 5.7% for those with the Medtronic-Hall (p = NS). The survivors were followed for 3 to 5 years (mean, 4.2 +/- 0.6 years; cumulative follow-up, 559 patient-years). Late mortality was 7.1%/patient-year for the St. Jude group and 3.2%/patient-year for the Medtronic-Hall group (p less than 0.05). However, the valve-related mortality was equal (1.4%/patient-year) for both groups. Noncardiac causes accounted for most of the difference between the St. Jude and Medtronic-Hall groups (2.5%/patient-year and 0.4%/patient-year, respectively). There were no cases of thrombotic obstruction, whereas serious systemic thromboembolism occurred at the rate of 1.8%/patient- year (5 episodes) for the St. Jude group and 2.5%/patient-year (7 episodes) for the Medtronic-Hall group (p = not significant); there were another nine episodes of systemic embolism that left no sequelae. Three patients (St. Jude, 2; Medtronic-Hall, 1), all of whom had aortic valve replacement, required reoperation (0.5%/patient-year) because of prosthetic endocarditis, with two deaths.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Card Surg AdultHome page
N. D. Desai and G. T. Christakis
Bioprosthetic Aortic Valve Replacement: Stented Pericardial and Porcine Valves
Card. Surg. Adult, January 1, 2008; 3(2008): 857 - 894.
[Full Text]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
V. Kutay, K. Kirali, H. Ekim, and C. Yakut
Effects of Giant Left Atrium on Thromboembolism after Mitral Valve Replacement
Asian Cardiovasc Thorac Ann, June 1, 2005; 13(2): 107 - 111.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Y. Wu, R. Gregorio, A. Renzulli, F. Onorati, M. De Feo, G. Grunkemeier, and M. Cotrufo
Mechanical heart valves: Are two leaflets better than one?
J. Thorac. Cardiovasc. Surg., April 1, 2004; 127(4): 1171 - 1179.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
N. D. Desai and G. T. Christakis
Stented Mechanical/Bioprosthetic Aortic Valve Replacement
Card. Surg. Adult, January 1, 2003; 2(2003): 825 - 856.
[Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
W.R. E. Jamieson, R. T. Miyagishima, G. L. Grunkemeier, E. Germann, C. Henderson, G. J. Fradet, L. H. Burr, and S. V. Lichtenstein
Bileaflet mechanical prostheses performance in mitral position
Eur. J. Cardiothorac. Surg., June 1, 1999; 15(6): 786 - 794.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. C. Fiore, H. B. Barner, M. T. Swartz, L. R. McBride, A. J. Labovitz, K. J. Vaca, J. St. Vrain, G. L. Grunkemeier, and G. C. Kaiser
Mitral valve replacement: randomized trial of St. Jude and Medtronic Hall prostheses
Ann. Thorac. Surg., September 1, 1998; 66(3): 707 - 713.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. E.E. Kuntze, E. H. Blackstone, and T. Ebels
Thromboembolism and mechanical heart valves: a randomized study revisited
Ann. Thorac. Surg., July 1, 1998; 66(1): 101 - 107.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
W.R. E. Jamieson, A. I. Munro, R. T. Miyagishima, G. L. Grunkemeier, L. H. Burr, S. V. Lichtenstein, and G. F. O. Tyers
Multiple mechanical valve replacement surgery comparison of St. Jude Medical and CarboMedics prostheses
Eur. J. Cardiothorac. Surg., February 1, 1998; 13(2): 151 - 159.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Abe, K. Kamata, K. Kuwaki, K. Komatsu, and S. Komatsu
Ten Years' Experience of Aortic Valve Replacement With the Omnicarbon Valve Prosthesis
Ann. Thorac. Surg., April 1, 1996; 61(4): 1182 - 1187.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
C. W. Akins
Long-Term Results With the Medtronic-Hall Valvular Prosthesis
Ann. Thorac. Surg., March 1, 1996; 61(3): 806 - 813.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
A. E. Fiane, K. Saatvedt, J. L. Svennevig, O. Geiran, K. Nordstrand, and T. Froysaker
The CarboMedics Valve: Midterm Follow-up With Analysis of Risk Factors
Ann. Thorac. Surg., October 1, 1995; 60(4): 1053 - 1058.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. G. Masters, A. L. Pipe, V. M. Walley, and W. J. Keon
Comparative results with the St. Jude Medical and Medtronic Hall mechanical valves
J. Thorac. Cardiovasc. Surg., September 1, 1995; 110(3): 663 - 671.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
A. C. Fiore, M. T. Swartz, T. G. Sharp, K. A. Kesler, H. B. Barner, K. S. Naunheim, G. L. Grunkemeier, D. A. Moroney, and G. C. Kaiser
Double-Valve Replacement With Medtronic-Hall or St. Jude Valve
Ann. Thorac. Surg., May 1, 1995; 59(5): 1113 - 1119.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Ibrahim, H. O'Kane, J. Cleland, D. Gladstone, M. Sarsam, and C. Patterson
The St. Jude Medical prosthesisA thirteen-year experience
J. Thorac. Cardiovasc. Surg., August 1, 1994; 108(2): 221 - 230.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1990 by The Society of Thoracic Surgeons.