A single-donor fibrin sealant system was used in 689 thoracic and
cardiovascular surgical procedures over the 4-year period between April 1,
1985, and March 31, 1989. An excellent overall success rate (646/689, 94%
effective) was achieved with specific applications, including reduction of
leakage of air (29/33, 88% effective), blood (595/634, 94% effective), and
fluid (14/14, 100% effective), as well as positioning of anatomical
structures such as coronary bypass grafts (8/8, 100% effective).
Application methods included use of spray bottles (477/497, 96% effective),
syringes (165/186, 89% effective), and a Silastic cannula through the
flexible fiber-optic bronchoscope (4/6, 67% effective). The system was used
in a wide variety of cardiac, pulmonary, esophageal, and vascular
procedures to seal staple lines, suture lines, anastomoses, conduits,
fistulas, and raw surfaces. No complications with this single-donor system
secondary to blood-borne disease have been documented. Overall infection
occurred at a nominal rate (16/689, 2%). Thus, fibrin sealant has been a
useful tool to control the leakage of air, blood, and fluid during a wide
variety of thoracic and cardiovascular procedures and may be of benefit to
other surgeons.
ARTICLES
Four years' experience with fibrin sealant in thoracic and cardiovascular surgery
Department of Surgery, University of Virginia Health Sciences Center, Charlottesville 22908.
This article has been cited by other articles:
![]() |
M. Eto, S. Morita, M. Sugiura, T. Yoshimura, R. Tominaga, and T. Matsuda Elastomeric surgical sealant for hemostasis of cardiovascular anastomosis under full heparinization Eur. J. Cardiothorac. Surg., November 1, 2007; 32(5): 730 - 734. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Garner and R. Brown Recent advances in topical agents for prehospital haemostasis Trauma, October 1, 2002; 4(4): 203 - 209. [Abstract] [PDF] |
||||
![]() |
M. E. JONES, S. BURNETT, A. SOUTHGATE, P. SIBBONS, A. O. GROBBELAAR, and C. J. GREEN The Role of Human-Derived Fibrin Sealant in the Reduction of Postoperative Flexor Tendon Adhesion Formation in Rabbits J Hand Surg Eur Vol., June 1, 2002; 27(3): 278 - 282. [Abstract] [PDF] |
||||
![]() |
H. L. Porte, T. Jany, R. Akkad, M. Conti, P. A. Gillet, A. Guidat, and A. J. Wurtz Randomized controlled trial of a synthetic sealant for preventing alveolar air leaks after lobectomy Ann. Thorac. Surg., May 1, 2001; 71(5): 1618 - 1622. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. D. Mintz, L. Mayers, N. Avery, H. L. Flanagan, S. G. Burks, and W. D. Spotnitz Fibrin Sealant: Clinical Use and the Development of the University of Virginia Tissue Adhesive Center Ann. Clin. Lab. Sci., January 1, 2001; 31(1): 108 - 118. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Feito, A. M. Rath, E. Longchampt, and J. Azorin Experimental study on the in vivo behaviour of a new collagen glue in lung surgery Eur. J. Cardiothorac. Surg., January 1, 2000; 17(1): 8 - 13. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Thistlethwaite, J. D. Luketich, P. F. Ferson, R. J. Keenan, and S. W. Jamieson Ablation of persistent air leaks after thoracic procedures with fibrin sealant Ann. Thorac. Surg., February 1, 1999; 67(2): 575 - 577. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Kawashima, T. Hirai, M. Kamiyoshihara, S. Ishikawa, and Y. Morishita Use of a Pericardial Fat Pad for Alveolar Air Leaks After Pulmonary Resections Asian Cardiovasc Thorac Ann, June 1, 1998; 6(2): 115 - 117. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Holcomb, M. MacPhee, S. Hetz, R. Harris, A. Pusateri, and J. Hess Efficacy of a Dry Fibrin Sealant Dressing for Hemorrhage Control After Ballistic Injury Arch Surg, January 1, 1998; 133(1): 32 - 35. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Larson, J. C. Bowersox, R. C. Lim Jr, and J. R. Hess Efficacy of a Fibrin Hemostatic Bandage in Controlling Hemorrhage From Experimental Arterial Injuries Arch Surg, April 1, 1995; 130(4): 420 - 422. [Abstract] [PDF] |
||||
![]() |
D. H. Sierra Fibrin Sealant Adhesive Systems: A Review of Their Chemistry, Material Properties and Clinical Applications J Biomater Appl, January 1, 1993; 7(4): 309 - 352. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |