ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bavaria, J. E.
Right arrow Articles by Edmunds, L. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bavaria, J. E.
Right arrow Articles by Edmunds, L. H., Jr

The Annals of Thoracic Surgery, Vol 49, 123-128, Copyright © 1990 by The Society of Thoracic Surgeons


ARTICLES

Effect of circulatory assist devices on stunned myocardium

JE Bavaria, S Furukawa, G Kreiner, KB Gupta, J Streicher and LH Edmunds Jr
Department of Surgery, School of Medicine, University of Pennsylvania, Philadelphia 19104.

We studied the effects of mechanical circulatory assist devices on left ventricular oxygen consumption, the integrals of systolic left ventricular wall stress (SSI), and end-systolic elastance (Ees) in 8 sheep after 25 minutes of global ischemia. Extracorporeal membrane oxygenation at 35 mL/kg/min, intraaortic balloon counterpulsation, and an intraaortic double-balloon pump were studied alone or in combination. Left ventricular oxygen consumption, SSI, and Ees were measured before and during mechanical circulatory assistance. Left ventricular oxygen consumption was calculated from transit-time measurements of left main coronary artery blood flow and fiberoptic measurements of coronary sinus blood oxygen saturation. Three pairs of sonomicrometry crystals placed across three orthogonal ventricular axes were used to calculate instantaneous ventricular volumes and pressure- volume loops from which the SSI data were derived. The Ees was measured using a new single-beat aortic occlusive method. Extracorporeal membrane oxygenation alone increased SSI and did not change Ees in postischemic poorly contracting hearts. Intraaortic balloon counterpulsation alone significantly reduced SSI and increased Ees. The combination of extracorporeal membrane oxygenation and either the intraaortic balloon pump or the intraaortic double-balloon pump reduced SSI, increased Ees, and reduced left ventricular oxygen consumption. In postischemic dilated, poorly contracting hearts, the combination of extracorporeal membrane oxygenation and intraaortic balloon counterpulsation has important advantages over extracorporeal membrane oxygenation alone.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
E. C. McGee Jr., P. M. McCarthy, and N. Moazami
Temporary Mechanical Circulatory Support
Card. Surg. Adult, January 1, 2008; 3(2008): 507 - 534.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
D. Hoefer, E. Ruttmann, G. Poelzl, J. Kilo, C. Hoermann, R. Margreiter, G. Laufer, and H. Antretter
Outcome evaluation of the bridge to bridge concept in patients with cardiogenic shock.
Ann. Thorac. Surg., July 1, 2006; 82(1): 28 - 33.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
Y. Oishi, M. Masuda, K.-i. Imasaka, S. Morita, and H. Yasui
Limitation of Venoarterial Bypass. Early Predictor and Optimal Conversion
Asian Cardiovasc Thorac Ann, June 1, 2005; 13(2): 167 - 171.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Nordhaug, T. Steensrud, S. Muller, K. V. Husnes, and T. Myrmel
Intraaortic Balloon Pumping Improves Hemodynamics and Right Ventricular Efficiency in Acute Ischemic Right Ventricular Failure
Ann. Thorac. Surg., October 1, 2004; 78(4): 1426 - 1432.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
N. Moazami and P. M. McCarthy
Temporary Circulatory Support
Card. Surg. Adult, January 1, 2003; 2(2003): 495 - 520.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
Q. Abid, P. Sitarama Rao, and S. W.H. Kendall
Use of intraaortic balloon pump in left ventricle rupture after mitral valve replacement
Ann. Thorac. Surg., December 1, 2002; 74(6): 2194 - 2195.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. A. Acker
Mechanical circulatory support for patients with acute-fulminant myocarditis
Ann. Thorac. Surg., March 1, 2001; 71 (2007): S73 - S76.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Kawaguchi, W. E. Pae, B. B. Daily, and W. S. Pierce
VENTRICULOARTERIAL COUPLING WITH INTRA-AORTIC BALLOON PUMP IN ACUTE ISCHEMIC HEART FAILURE
J. Thorac. Cardiovasc. Surg., January 1, 1999; 117(1): 164 - 171.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
N. G. Smedira, C. C. Hlozek, and P. M. McCarthy
Mechanical Support After Cardiac Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1998; 2(1): 66 - 77.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. J. DeRose Jr, J. P. Umana, M. Argenziano, K. A. Catanese, H. R. Levin, B. C. Sun, E. A. Rose, and M. C. Oz
Improved Results for Postcardiotomy Cardiogenic Shock With the Use of Implantable Left Ventricular Assist Devices
Ann. Thorac. Surg., December 1, 1997; 64(6): 1757 - 1762.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
D. D. Muehrcke, P. M. McCarthy, R. W. Stewart, R. C. Foster, D. A. Ogella, J. A. Borsh, and D. M. Cosgrove III
Extracorporeal Membrane Oxygenation for Postcardiotomy Cardiogenic Shock
Ann. Thorac. Surg., February 1, 1996; 61(2): 684 - 691.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1990 by The Society of Thoracic Surgeons.