|
|
||||||||
The Annals of Thoracic Surgery, Vol 49, 123-128, Copyright © 1990 by The Society of Thoracic Surgeons
JE Bavaria, S Furukawa, G Kreiner, KB Gupta, J Streicher and LH Edmunds Jr
We studied the effects of mechanical circulatory assist devices on left
ventricular oxygen consumption, the integrals of systolic left ventricular
wall stress (SSI), and end-systolic elastance (Ees) in 8 sheep after 25
minutes of global ischemia. Extracorporeal membrane oxygenation at 35
mL/kg/min, intraaortic balloon counterpulsation, and an intraaortic
double-balloon pump were studied alone or in combination. Left ventricular
oxygen consumption, SSI, and Ees were measured before and during mechanical
circulatory assistance. Left ventricular oxygen consumption was calculated
from transit-time measurements of left main coronary artery blood flow and
fiberoptic measurements of coronary sinus blood oxygen saturation. Three
pairs of sonomicrometry crystals placed across three orthogonal ventricular
axes were used to calculate instantaneous ventricular volumes and pressure-
volume loops from which the SSI data were derived. The Ees was measured
using a new single-beat aortic occlusive method. Extracorporeal membrane
oxygenation alone increased SSI and did not change Ees in postischemic
poorly contracting hearts. Intraaortic balloon counterpulsation alone
significantly reduced SSI and increased Ees. The combination of
extracorporeal membrane oxygenation and either the intraaortic balloon pump
or the intraaortic double-balloon pump reduced SSI, increased Ees, and
reduced left ventricular oxygen consumption. In postischemic dilated,
poorly contracting hearts, the combination of extracorporeal membrane
oxygenation and intraaortic balloon counterpulsation has important
advantages over extracorporeal membrane oxygenation alone.
ARTICLES
Effect of circulatory assist devices on stunned myocardium
Department of Surgery, School of Medicine, University of Pennsylvania, Philadelphia 19104.
This article has been cited by other articles:
![]() |
E. C. McGee Jr., P. M. McCarthy, and N. Moazami Temporary Mechanical Circulatory Support Card. Surg. Adult, January 1, 2008; 3(2008): 507 - 534. [Full Text] |
||||
![]() |
D. Hoefer, E. Ruttmann, G. Poelzl, J. Kilo, C. Hoermann, R. Margreiter, G. Laufer, and H. Antretter Outcome evaluation of the bridge to bridge concept in patients with cardiogenic shock. Ann. Thorac. Surg., July 1, 2006; 82(1): 28 - 33. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Oishi, M. Masuda, K.-i. Imasaka, S. Morita, and H. Yasui Limitation of Venoarterial Bypass. Early Predictor and Optimal Conversion Asian Cardiovasc Thorac Ann, June 1, 2005; 13(2): 167 - 171. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Nordhaug, T. Steensrud, S. Muller, K. V. Husnes, and T. Myrmel Intraaortic Balloon Pumping Improves Hemodynamics and Right Ventricular Efficiency in Acute Ischemic Right Ventricular Failure Ann. Thorac. Surg., October 1, 2004; 78(4): 1426 - 1432. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Moazami and P. M. McCarthy Temporary Circulatory Support Card. Surg. Adult, January 1, 2003; 2(2003): 495 - 520. [Full Text] |
||||
![]() |
Q. Abid, P. Sitarama Rao, and S. W.H. Kendall Use of intraaortic balloon pump in left ventricle rupture after mitral valve replacement Ann. Thorac. Surg., December 1, 2002; 74(6): 2194 - 2195. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Acker Mechanical circulatory support for patients with acute-fulminant myocarditis Ann. Thorac. Surg., March 1, 2001; 71 (2007): S73 - S76. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Kawaguchi, W. E. Pae, B. B. Daily, and W. S. Pierce VENTRICULOARTERIAL COUPLING WITH INTRA-AORTIC BALLOON PUMP IN ACUTE ISCHEMIC HEART FAILURE J. Thorac. Cardiovasc. Surg., January 1, 1999; 117(1): 164 - 171. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. G. Smedira, C. C. Hlozek, and P. M. McCarthy Mechanical Support After Cardiac Surgery Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1998; 2(1): 66 - 77. [Abstract] [PDF] |
||||
![]() |
J. J. DeRose Jr, J. P. Umana, M. Argenziano, K. A. Catanese, H. R. Levin, B. C. Sun, E. A. Rose, and M. C. Oz Improved Results for Postcardiotomy Cardiogenic Shock With the Use of Implantable Left Ventricular Assist Devices Ann. Thorac. Surg., December 1, 1997; 64(6): 1757 - 1762. [Abstract] [Full Text] |
||||
![]() |
D. D. Muehrcke, P. M. McCarthy, R. W. Stewart, R. C. Foster, D. A. Ogella, J. A. Borsh, and D. M. Cosgrove III Extracorporeal Membrane Oxygenation for Postcardiotomy Cardiogenic Shock Ann. Thorac. Surg., February 1, 1996; 61(2): 684 - 691. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |