ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Molina, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Molina, J. E.

The Annals of Thoracic Surgery, Vol 48, 624-627, Copyright © 1989 by The Society of Thoracic Surgeons


ARTICLES

Nonreversed saphenous vein grafts for coronary artery bypass grafting

JE Molina
Division of Cardiovascular and Thoracic Surgery, University of Minnesota Medical School, Minneapolis.

Between August 1985 and December 1988, valvotomized saphenous vein grafts were used in 365 patients undergoing coronary artery bypass grafting (CABG). In this operation, the femoral end of the vein is attached to the aorta and the pedal end is attached to the coronary artery. Vein diameters measured 8 +/- 2 mm at the femoral end, 4.5 +/- 1.2 mm at the knee level, and 3.5 +/- 1.3 mm at the ankle. Ratios between levels were as follows: knee to femoral end, 0.56, and ankle to femoral end, 0.43. The ratio of knee to femoral end was 0.42 in cases with vein midthigh bifurcation. There were 1,310 grafts implanted (3.6 per patient). In 341 patients, CABG alone was performed, and 24 patients had combined procedures: 11 had CABG with mitral valve replacement, 9 had CABG with aortic valve replacement, 2 had CABG with repair of postinfarct ventricular septal defect, and 2 had CABG with automatic defibrillator implantation. Follow-up (up to 3.5 years) was attained in 97% of patients. For various reasons, 34 patients had a second angiogram between 3 and 41 months postoperatively. Of 120 vein grafts, 108 (90%) were patent. At autopsy, 11 patients with 45 vein grafts had 43 patent and clean grafts and two thrombosed. Use of nonreversed saphenous vein for coronary bypass is recommended. It assures a large proximal anastomosis, natural vein bifurcations can be used with fewer proximal anastomoses, better vein-coronary artery size matching is obtained, and the patency rate is satisfactory.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1989 by The Society of Thoracic Surgeons.