ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Niebauer, G. W.
Right arrow Articles by Lemole, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Niebauer, G. W.
Right arrow Articles by Lemole, G.

The Annals of Thoracic Surgery, Vol 48, 523-527, Copyright © 1989 by The Society of Thoracic Surgeons


ARTICLES

Simultaneous use of microfibrillar collagen hemostat and blood saving devices in a canine kidney perfusion model

GW Niebauer, MC Oz, M Goldschmidt and G Lemole
School of Veterinary Medicine, Department of Clinical Studies, University of Pennsylvania, Philadelphia.

Intraoperative autotransfusion and topical microfibrillar collagen hemostats have been increasingly used, often simultaneously, in various surgical procedures to minimize intraoperative blood loss and thus reduce the inherent risks of homologous blood transfusion. As moderate amounts of small particles have been shown to pass through filtering devices during intraoperative autotransfusion, concern has been raised over the amount of heterologous collagen fibrils transfused and their effect on the host. We found that 2% of microfibrillar collagen hemostat particles pass through the 20-microns millipore filter contained in the tested autotransfusion device (William Harvey H-4700 cardiotomy reservoir). Using a canine kidney perfusion model, we found multifocal perivascular inflammatory reactions within the renal parenchyma five days after transfusion of filtered autologous blood containing minute amounts of microfibrillar collagen hemostat. The findings demonstrate a strong inflammatory foreign body response to heterologous collagen particles trapped in the microcirculation of the perfused kidneys. It is concluded that despite using filters with a pore size of 20 microns, using intraoperative autotransfusion and microfibrillar collagen hemostats simultaneously creates a potential risk because adverse reactions can be elicited especially within the microvasculature of tissues containing end-arterial circulation.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Sirlak
Reply to the Editor
J. Thorac. Cardiovasc. Surg., April 1, 2004; 127(4): 1228 - 1228.
[Full Text] [PDF]


Home page
PerfusionHome page
M H Cross
Cell salvage and leucodepletion
Perfusion, January 1, 2001; 16(1_suppl): 61 - 66.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. C. Oz, D. M. Cosgrove III, B. R. Badduke, J. D. Hill, M. R. Flannery, R. Palumbo, and N. Topic
Controlled clinical trial of a novel hemostatic agent in cardiac surgery
Ann. Thorac. Surg., May 1, 2000; 69(5): 1376 - 1382.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. S. McKIE and J. E. HERZENBERG
Coagulopathy Complicating Intraoperative Blood Salvage in a Patient Who Had Idiopathic Scoliosis. A Case Report
J. Bone Joint Surg. Am., September 1, 1997; 79(9): 1391 - 4.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1989 by The Society of Thoracic Surgeons.