ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kontos, G. J.
Right arrow Articles by Danielson, G. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kontos, G. J., Jr
Right arrow Articles by Danielson, G. K.

The Annals of Thoracic Surgery, Vol 48, 60-65, Copyright © 1989 by The Society of Thoracic Surgeons


ARTICLES

Thrombotic obstruction of disc valves: clinical recognition and surgical management

GJ Kontos Jr, HV Schaff, TA Orszulak, FJ Puga, JR Pluth and GK Danielson
Section of Thoracic and Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota 55905.

Twenty-seven patients underwent reoperation because of thrombotic obstruction of a disc-type cardiac valve prosthesis. Preoperative clinical features included effort dyspnea in 81%, new-onset angina in 44%, a new murmur in 89%, and an abnormal opening or closing sound associated with the prosthetic valve in 56%. Symptoms were present for 1 week or more before reoperation in 86%, although many patients were referred only after acute exacerbation of heart failure and development of pulmonary edema. Noninvasive studies confirmed prosthetic valve malfunction in only 33%, but cardiac catheterization documented thrombotic obstruction in all 15 patients in whom it was performed. In 14 of the 27 patients, prothrombin time was in the therapeutic range at the time of admission. Prompt reoperation for valve replacement or thrombectomy was performed with an operative mortality of 11%, and long- term outcome was satisfactory in all but 1 hospital survivor. These findings emphasize the importance of considering the diagnosis of thrombosed heart valves in patients with mechanical heart valves who are seen with nonspecific symptoms.


This article has been cited by other articles:


Home page
ICVTSHome page
U. Dandekar, M. Kalkat, and C. Smallpeice
Fatal early acute thrombosis of mechanical mitral prosthesis
Interactive CardioVascular and Thoracic Surgery, August 1, 2006; 5(4): 460 - 461.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. D. Potter, T. M. Sundt III, K. J. Zehr, J. A. Dearani, R. C. Daly, C. J. Mullany, C. G.A. McGregor, F. J. Puga, H. V. Schaff, and T. A. Orszulak
Operative risk of reoperative aortic valve replacement
J. Thorac. Cardiovasc. Surg., January 1, 2005; 129(1): 94 - 103.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
H.P. Kuhl and P. Hanrath
The impact of transesophageal echocardiography on daily clinical practice
Eur J Echocardiogr, December 1, 2004; 5(6): 455 - 468.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. Durrleman, M. Pellerin, D. Bouchard, Y. Hebert, R. Cartier, L. P. Perrault, A. Basmadjian, and M. Carrier
Prosthetic valve thrombosis: Twenty-year experience at the Montreal Heart Institute
J. Thorac. Cardiovasc. Surg., May 1, 2004; 127(5): 1388 - 1392.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. T. Tong, R. Roudaut, M. Ozkan, A. Sagie, M. S. A. Shahid, S. C. Pontes Jr, F. Carreras, S. E. Girard, S. Arnaout, R. F. Stainback, et al.
Transesophageal echocardiography improves risk assessment of thrombolysis of prosthetic valve thrombosis: results of the international PRO-TEE registry
J. Am. Coll. Cardiol., January 7, 2004; 43(1): 77 - 84.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
S. B Kale, D. S Saksena, Y. C Agnihotri, and K. H Ayyer
Thrombectomy With Disc Rotation of Medtronic Valves
Asian Cardiovasc Thorac Ann, December 1, 2003; 11(4): 309 - 313.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. Montorsi, D. Cavoretto, M. Alimento, M. Muratori, and M. Pepi
Prosthetic Mitral Valve Thrombosis: Can Fluoroscopy Predict the Efficacy of Thrombolytic Treatment?
Circulation, September 9, 2003; 108(90101): II-79 - 84.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
D. Hering, C. Piper, and D. Horstkotte
Management of prosthetic valve thrombosis
Eur. Heart J. Suppl., December 1, 2001; 3(suppl_Q): Q22 - Q26.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
S. E. Girard, F. A. Miller Jr., T. A. Orszulak, C. J. Mullany, S. Montgomery, W. D. Edwards, H. D. Tazelaar, J. F. Malouf, and A. J. Tajik
Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings
J. Am. Coll. Cardiol., February 1, 2001; 37(2): 579 - 584.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Ozkan, C. Kaymaz, C. Kirma, K. Sonmez, N. Ozdemir, M. Balkanay, C. Yakut, and U. Deligonul
Intravenous thrombolytic treatment of mechanical prosthetic valve thrombosis: a study using serial transesophageal echocardiography
J. Am. Coll. Cardiol., June 1, 2000; 35(7): 1881 - 1889.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. Barbetseas, S. F. Nagueh, C. Pitsavos, P. K. Toutouzas, M. A. Quinones, and W. A. Zoghbi
Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters
J. Am. Coll. Cardiol., November 1, 1998; 32(5): 1410 - 1417.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Vitale, A. Renzulli, L. Agozzino, A. Pollice, N. Tedesco, L. d. L. T. Schinosa, and M. Cotrufo
Obstruction of Mechanical Mitral Prostheses: Analysis of Pathologic Findings
Ann. Thorac. Surg., April 1, 1997; 63(4): 1101 - 1106.
[Abstract] [Full Text]


Home page
NEJMHome page
W. Vongpatanasin, L. D. Hillis, and R. A. Lange
Prosthetic Heart Valves
N. Engl. J. Med., August 8, 1996; 335(6): 407 - 416.
[Full Text] [PDF]


Home page
CirculationHome page
P. Gueret, P. Vignon, P. Fournier, J.-M. Chabernaud, M. Gomez, P. LaCroix, and J. Bensaid
Transesophageal Echocardiography for the Diagnosis and Management of Nonobstructive Thrombosis of Mechanical Mitral Valve Prosthesis
Circulation, January 1, 1995; 91(1): 103 - 110.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1989 by The Society of Thoracic Surgeons.