ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Perier, P.
Right arrow Articles by Carpentier, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Perier, P.
Right arrow Articles by Carpentier, A.

The Annals of Thoracic Surgery, Vol 48, 54-59, Copyright © 1989 by The Society of Thoracic Surgeons


ARTICLES

A 10-year comparison of mitral valve replacement with Carpentier- Edwards and Hancock porcine bioprostheses

P Perier, A Deloche, S Chauvaud, JC Chachques, J Relland, JN Fabiani, Y Stephan, P Blondeau and A Carpentier
Department of Cardiovascular Surgery, Hopital Broussais, Paris, France.

Two hundred fifty-three patients who underwent isolated mitral valve replacement with a porcine bioprosthesis had long-term evaluation. One hundred forty-seven patients received a Carpentier-Edwards porcine bioprosthesis and 106, a Hancock valve. There were no significant differences in preoperative clinical characteristics between the two groups. Cumulative follow-up was 1,375 patient-years. At 10 years, 93% +/- 2.5% of the patients in the Carpentier-Edwards group and 85% +/- 7.8% of those in the Hancock group were free from valve-related death (not significant), and 95% +/- 2% and 91% +/- 3.8%, respectively, were free from thromboembolism (not significant). At 10 years, 65% +/- 7.2% of the patients in the Carpentier-Edwards group and 66% +/- 7.2% of those in the Hancock group were free from structural valve deterioration (not significant), and 64% +/- 6% and 59% +/- 7.3%, respectively, were free from reoperation (not significant). We conclude that the first generation of Carpentier-Edwards and Hancock prostheses produce comparable long-term results in the mitral position.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
T. Gudbjartsson, T. Absi, and S. Aranki
Mitral Valve Replacement
Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068.
[Full Text]


Home page
Card Surg AdultHome page
T. Gudbjartsson, S. Aranki, and L. H. Cohn
Mechanical/Bioprosthetic Mitral Valve Replacement
Card. Surg. Adult, January 1, 2003; 2(2003): 951 - 986.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
J. I. Fann, D. C. Miller, KathleenA. Moore, R. S. Mitchell, P. E. Oyer, E. B. Stinson, R. C. Robbins, B. A. Reitz, and N. E. Shumway
Twenty-Year Clinical Experience With Porcine Bioprostheses
Ann. Thorac. Surg., November 1, 1996; 62(5): 1301 - 1311.
[Abstract] [Full Text]


Home page
NEJMHome page
K. E. Hammermeister, G. K. Sethi, W. G. Henderson, C. Oprian, T. Kim, S. Rahimtoola, and The Veterans Affairs Cooperative Study on Valvular
A Comparison of Outcomes in Men 11 Years after Heart-Valve Replacement with a Mechanical Valve or Bioprosthesis
N. Engl. J. Med., May 6, 1993; 328(18): 1289 - 1296.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1989 by The Society of Thoracic Surgeons.