ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baker, J. W.
Right arrow Articles by Nolan, S. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baker, J. W.
Right arrow Articles by Nolan, S. P.

The Annals of Thoracic Surgery, Vol 47, 450-452, Copyright © 1989 by The Society of Thoracic Surgeons


ARTICLES

Mediastinal fibrin glue: hemostatic effect and tissue response in calves

JW Baker, WD Spotnitz, TL Matthew, RE Fechner and SP Nolan
Department of Surgery, University of Virginia School of Medicine, Charlottesville.

There is continued controversy regarding the effectiveness and potential adverse effects of fibrin glue. Thus, we chose to evaluate it in a model of experimental calf aortic valve replacement that has been previously well established. Concentrated fibrinogen and topical thrombin were sprayed to form a thin layer of fibrin glue over the mediastinal tissues of 20 consecutive calves undergoing aortic valve replacement. Chest tube outputs of these animals were compared with those of the preceding 20 consecutive calves undergoing aortic valve replacement without fibrin glue. All procedures were performed by the same surgeon, and no other technical changes were made between the two series. Total postoperative chest tube output (mean +/- standard error) was 553 +/- 50 mL for the calves treated with fibrin glue and 1,155 +/- 103 mL for the control calves (p less than 0.001). On histological examination of mediastinal tissues from 5 treated calves killed 6 weeks after operation, there was no evidence of inflammation, fibrosis, or residual fibrin. To our knowledge, this is the first controlled laboratory study to show that fibrin glue spray is an effective hemostatic agent and that it produces no long-term tissue reaction.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
R. Hattori, H. Otani, H. Omiya, S. Tabata, Y. Nakao, T. Yamamura, M. Osako, Y. Saito, and H. Imamura
Fate of fibrin sealant in pericardial space
Ann. Thorac. Surg., December 1, 2000; 70(6): 2132 - 2136.
[Abstract] [Full Text] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
S. K. Libutti, M. C. Oz, R. S. Chuck, M. R. Treat, and R. Nowygrod
Dye-Enhanced Tissue Welding Using Fibrinogen and Continuous-Wave Argon Lasers
Vascular and Endovascular Surgery, November 1, 1990; 24(9): 671 - 676.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1989 by The Society of Thoracic Surgeons.