ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Magovern, G. J.
Right arrow Articles by Cabrol, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Magovern, G. J.
Right arrow Articles by Cabrol, C.

The Annals of Thoracic Surgery, Vol 47, 102-107, Copyright © 1989 by The Society of Thoracic Surgeons


ARTICLES

Circulatory Support 1988. Weaning and bridging

GJ Magovern, LA Golding, PE Oyer and C Cabrol

After a patient has been supported with a circulatory assist device, the expected outcomes are weaning, bridging, or discontinuation of support. An early insertion of the device will avoid deterioration of the heart and other organs to an irreversible condition. Cardiac assistance for a minimum of 24 hours is recommended with a mild dose of anticoagulant. It is necessary to monitor the hemodynamic functions during circulatory support and weaning. Most of the mechanical devices are quite reliable, and complications during ventricular assist are easily managed. The patient should be in the same condition as in ordinary elective transplant candidate before transplantation. Patients with an artificial heart or ventricular assist device should not be on the priority emergency list for cardiac transplantation. Patients suffering from cardiogenic shock can be stabilized with a ventricular assist device to allow the heart to recover or be provided with other treatment. A circulatory support device can also be used as a bridge for patients awaiting a cardiac transplant.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
M. E. DeBakey
A miniature implantable axial flow ventricular assist device
Ann. Thorac. Surg., August 1, 1999; 68(2): 637 - 640.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. A. Hunt and O.H. Frazier
Mechanical Circulatory Support and Cardiac Transplantation
Circulation, May 26, 1998; 97(20): 2079 - 2090.
[Full Text] [PDF]


Home page
CirculationHome page
J. Muller, G. Wallukat, Y.-G. Weng, M. Dandel, S. Spiegelsberger, S. Semrau, K. Brandes, V. Theodoridis, M. Loebe, R. Meyer, et al.
Weaning From Mechanical Cardiac Support in Patients With Idiopathic Dilated Cardiomyopathy
Circulation, July 15, 1997; 96(2): 542 - 549.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
H. Takano and T. Nakatani
Ventricular Assist Systems: Experience in Japan With Toyobo Pump and Zeon Pump
Ann. Thorac. Surg., January 1, 1996; 61(1): 317 - 322.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Kawaguchi, J. S. Sapirstein, W. B. Daily, W. E. Pae, and W. S. Pierce
Linear end-systolic pressure-volume relationship during pulsatile left ventricular bypass represents native heart function
J. Thorac. Cardiovasc. Surg., April 1, 1995; 109(4): 780 - 786.