ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Okita, Y.
Right arrow Articles by Shiraishi, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Okita, Y.
Right arrow Articles by Shiraishi, S.

The Annals of Thoracic Surgery, Vol 46, 89-92, Copyright © 1988 by The Society of Thoracic Surgeons


ARTICLES

Intractable hemolysis caused by perivalvular leakage following mitral valve replacement with St. Jude Medical prosthesis

Y Okita, S Miki, K Kusuhara, Y Ueda, T Tahata, Y Tsukamoto, K Yamanaka and S Shiraishi
Department of Cardiovascular Surgery, Tenri Hospital, Nara, Japan.

Nine patients with intractable hemolysis caused by perivalvular leakage following mitral valve replacement with a St. Jude Medical prosthesis are presented. All patients had dark-colored hemoglobinuria, which appeared from 1 day to 44 days after the operation, with moderate or severe hepatorenal insufficiency. One patient died of multiorgan failure. The other 8 patients underwent reoperation, and all survived. Reoperation revealed that all leakages were tiny and had no adverse effect on hemodynamics. In all the patients having reoperation, hemoglobinuria disappeared immediately after the procedure. Surface- scanning electron microscopy of the sewing cuff of the St. Jude Medical prosthesis revealed the rough surface structure of the sewing ring. Because of this irregular, shaggy surface structure, greater shearing forces against erythrocytes can be generated when there is perivalvular leakage.


This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
S. Aoyagi, S. Fukunaga, E. Tayama, E. Nakamura, N. Egawa, and Y. Hosokawa
Benefits of a {beta}-Blocker for Intractable Hemolysis due to Paraprosthetic Leakage
Asian Cardiovasc Thorac Ann, October 1, 2007; 15(5): 441 - 443.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Josa, M. Castella, C. Pare, J. L. Bedini, R. Cartana, C. A. Mestres, J. L. Pomar, and J. Mulet
Hemolysis in Mechanical Bileaflet Prostheses: Experience With the Bicarbon Valve
Ann. Thorac. Surg., April 1, 2006; 81(4): 1291 - 1296.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Aoyagi, A. Oryoji, Y. Nishi, K. Tanaka, K. Kosuga, and K. Oishi
Long-term results of valve replacement with the St. Jude Medical valve
J. Thorac. Cardiovasc. Surg., December 1, 1994; 108(6): 1021 - 1029.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1988 by The Society of Thoracic Surgeons.