The Annals of Thoracic Surgery, Vol 45, 203-205, Copyright © 1988 by The Society of Thoracic Surgeons
PM McCarthy, VF Trastek, DG Bell, GR Buttermann, JM Piehler, WS Payne, LH Weiland and PC Pairolero
The effectiveness of fibrin glue as a biological sealant for pulmonary air
leaks was determined in 16 dogs. A standardized pleural defect was made in
the left lower lobe, and the quantity of air passing through a chest tube
was assessed with a Collins respirometer. For the 8 randomly assigned
control animals, the air leak decreased over 90 minutes from a mean of 1.4
L/min to a mean of 1.1 L/min (mean decrease, 19.8%). In the 8 randomly
assigned fibrin glue-treated animals, the air leak decreased from a mean of
2.1 L/min to a mean of 0.5 L/min (mean decrease, 80.8%) (p less than
0.0001). Postoperative evaluation of survivors disclosed no increased
adhesions in the glue-treated animals and complete resorption of the glue
at 3 months. We conclude that in this animal model, fibrin glue reduced the
size of pulmonary air leaks in the early period after thoracotomy and did
not lead to increased intrapleural adhesions.
ARTICLES
The effectiveness of fibrin glue sealant for reducing experimental pulmonary ari leak
Section of Thoracic and Cardiovascular Surgery, Mayo Clinic, Rochester, MN 55905.
This article has been cited by other articles:
![]() |
M. Kanzaki, M. Yamato, J. Yang, H. Sekine, R. Takagi, T. Isaka, T. Okano, and T. Onuki Functional closure of visceral pleural defects by autologous tissue engineered cell sheets Eur. J. Cardiothorac. Surg., October 1, 2008; 34(4): 864 - 869. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Tansley, F. Al-Mulhim, E. Lim, G. Ladas, and P. Goldstraw A prospective, randomized, controlled trial of the effectiveness of BioGlue in treating alveolar air leaks J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 105 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Matsumoto, Y. Ohta, M. Oda, Y. Tsunezuka, M. Tamura, K. Kawakami, and G. Watanabe Free Pericardial Fat Pads Can Act as Sealant for Preventing Alveolar Air Leaks Ann. Thorac. Surg., December 1, 2005; 80(6): 2321 - 2324. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Lois and M. Noppen Bronchopleural Fistulas: An Overview of the Problem With Special Focus on Endoscopic Management Chest, December 1, 2005; 128(6): 3955 - 3965. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Allen, D. E. Wood, R. W. Hawkinson, D. H. Harpole, R. J. McKenna, G. L. Walsh, E. Vallieres, D. L. Miller, F. C. Nichols III, W. R. Smythe, et al. Prospective randomized study evaluating a biodegradable polymeric sealant for sealing intraoperative air leaks that occur during pulmonary resection Ann. Thorac. Surg., May 1, 2004; 77(5): 1792 - 1801. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. P. Brega Massone, B. Magnani, B. Conti, C. Lequaglie, and I. Cataldo Cauterization Versus Fibrin Glue for Aerostasis in Precision Resections for Secondary Lung Tumors Ann. Surg. Oncol., May 1, 2003; 10(4): 441 - 446. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Fabian, J. A. Federico, and R. B. Ponn Fibrin glue in pulmonary resection: a prospective, randomized, blinded study Ann. Thorac. Surg., May 1, 2003; 75(5): 1587 - 1592. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. W. Herget, M. Kassa, U. N. Riede, Y. Lu, L. Brethner, and J. Hasse Experimental use of an albumin-glutaraldehyde tissue adhesive for sealing pulmonary parenchyma and bronchial anastomoses Eur. J. Cardiothorac. Surg., January 1, 2001; 19(1): 4 - 9. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Nomori, H. Horio, and K. Suemasu Mixing collagen with fibrin glue to strengthen the sealing effect for pulmonary air leakage Ann. Thorac. Surg., November 1, 2000; 70(5): 1666 - 1670. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. K. Kjaergard, J. H. Pedersen, M. Krasnik, U. S. Weis-Fogh, H. Fleron, and H. E. Griffin Prevention of Air Leakage by Spraying Vivostat Fibrin Sealant After Lung Resection in Pigs Chest, April 1, 2000; 117(4): 1124 - 1127. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kinoshita, S. Miyoshi, M. Katoh, T. Yoshimasu, M. Juri, S. Maebeya, and Y. Naito Intrapleural Administration of a Large Amount of Diluted Fibrin Glue for Intractable Pneumothorax Chest, March 1, 2000; 117(3): 790 - 795. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Feito, A. M. Rath, E. Longchampt, and J. Azorin Experimental study on the in vivo behaviour of a new collagen glue in lung surgery Eur. J. Cardiothorac. Surg., January 1, 2000; 17(1): 8 - 13. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Otani, Y. Tabata, and Y. Ikada Sealing effect of rapidly curable gelatin-poly (L-glutamic acid) hydrogel glue on lung air leak Ann. Thorac. Surg., April 1, 1999; 67(4): 922 - 926. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Nomori, H. Horio, S. Morinaga, and K. Suemasu Gelatin-resorcinol-formaldehyde-glutaraldehyde glue for sealing pulmonary air leaks during thoracoscopic operation Ann. Thorac. Surg., January 1, 1999; 67(1): 212 - 216. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Wong and P. Goldstraw Effect of Fibrin Glue in the Reduction of Postthoracotomy Alveolar Air Leak Ann. Thorac. Surg., October 1, 1997; 64(4): 979 - 981. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |