ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van Oeveren, W.
Right arrow Articles by Wildevuur, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van Oeveren, W.
Right arrow Articles by Wildevuur, C. R.

The Annals of Thoracic Surgery, Vol 44, 523-528, Copyright © 1987 by The Society of Thoracic Surgeons


ARTICLES

Bubble oxygenation and cardiotomy suction impair the host defense during cardiopulmonary bypass: a study in dogs

W van Oeveren, J Dankert and CR Wildevuur
Department of Cardiopulmonary Surgery, University Hospital, Groningen, The Netherlands.

Decreased complement levels and impairment of polymorphonuclear leukocyte function increase the risk of infection during cardiopulmonary bypass (CPB). The effects of different types of oxygenator and of blood suction on this natural humoral and cellular host defense mechanism were investigated in dogs undergoing CPB during sham open-heart operations. Airborne contamination of the wound area and the CPB circuit was performed by aerosolizing Staphylococcus aureus. A membrane oxygenator in the CPB circuit maintained a normal host defense mechanism. The use of cardiotomy suction during CPB with this type of oxygenator affected the host defense to some extent. The use of a bubble oxygenator in the CPB circuit together with cardiotomy suction seriously impaired the host defense. Postoperatively bacteremia developed in no dogs in the membrane oxygenator group, whereas 8 of 15 dogs in the bubble oxygenator group had a positive blood culture for the indicator microorganism. We conclude that the use of a membrane oxygenator is helpful to maintain the host defense. Attention has to be paid to reduce the deleterious effects of cardiotomy suction.


This article has been cited by other articles:


Home page
PerfusionHome page
J W Mulholland, W Massey, and J C Shelton
Investigation and quantification of the blood trauma caused by the combined dynamic forces experienced during cardiopulmonary bypass
Perfusion, December 1, 2000; 15(6): 485 - 494.
[Abstract] [PDF]


Home page
PerfusionHome page
P. D Beckley, P. D Shinko, and J. P Sites
A comparison of gaseous emboli release in five membrane oxygenators
Perfusion, March 1, 1997; 12(2): 133 - 141.
[Abstract] [PDF]


Home page
PerfusionHome page
P. Hornick
Cardiopulmonary bypass and the adaptive immune system: perspectives on T cell function
Perfusion, May 1, 1996; 11(3): 281 - 290.
[PDF]


Home page
PerfusionHome page
J. R Utley, S. A Leyland, H. D Johnson, M. S Morgan, C. M Wilde, M. S Bell, M. M Sawaf, and B. S Harrison
Correlation of preoperative factors, severity of disease, type of oxygenator and perfusion times with mortality and morbidity of coronary bypass
Perfusion, January 1, 1991; 6(1): 15 - 22.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1987 by The Society of Thoracic Surgeons.