ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kusuhara, K.
Right arrow Articles by Komeda, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kusuhara, K.
Right arrow Articles by Komeda, M.

The Annals of Thoracic Surgery, Vol 44, 128-134, Copyright © 1987 by The Society of Thoracic Surgeons


ARTICLES

Optimal flow of aorta-pulmonary artery shunt in patients with cyanotic heart disease

K Kusuhara, S Miki, Y Ueda, Y Ohkita, T Tahata and M Komeda

An aorta-pulmonary artery shunt with an expanded polytetrafluoroethylene (Gore-Tex) tube graft (3 to 6 mm in diameter) was done in 33 cyanotic patients with complex congenital heart disease. The patients ranged from 14 days to 22 years old. In 28, the shunt flow (QB) was measured, and the optimal QB and graft size were determined. Nine patients had severe heart failure because of an excessively large shunt. Seven of these patients died, 5 early and 2 late after operation. The QBS in these 9 patients were extremely high; the QB index and the ratio of shunt flow to systemic flow (QB/QS) were 3.86 +/- 0.91 L/min/m2 (mean +/- standard deviation) and 52.4 +/- 9.7%, respectively. The QB index and the QB/QS of patients without severe cardiac failure were 1.49 +/- 0.92 L/min/m2 and 27.2 +/- 11.4%, respectively. In conclusion, the QB index, the QB/QS, or both should be maintained in the range of 1.6 to 2.4 L/min/m2 and 30 to 40%, respectively. In infants, however, it is advisable to control the flow at less than the range just given. Analysis of graft size in relation to body weight (BW, in kilograms) and body surface area (BSA, in square meters) showed that the optimal diameter (D, in millimeters) could be calculated by the following formulas: D = 1.88 In(BW) + 1.8 (r = .86) D = 0.87 In(BSA) + 5.3 (r = .73).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1987 by The Society of Thoracic Surgeons.