ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by DeCampli, W. M.
Right arrow Articles by Miller, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by DeCampli, W. M.
Right arrow Articles by Miller, D. C.

The Annals of Thoracic Surgery, Vol 42, 690-696, Copyright © 1986 by The Society of Thoracic Surgeons


ARTICLES

Pharmacological, hematological, and physiological effects of a new thromboxane synthetase inhibitor (CGS-13080) during cardiopulmonary bypass in dogs

WM DeCampli, D Goodwin, JC Kosek, CE Handen, RS Mitchell and DC Miller

The hematological and pharmacological effects of a new thromboxane synthetase inhibitor, CGS-13080 (imidazo[1,5-alpha]pyridine-5-hexanoic acid), were investigated during cardiopulmonary bypass in a blinded, randomized manner in dogs. Compared with placebo, CGS-13080 suppressed thrombin-stimulated platelet thromboxane B2 production by 90% during cardiopulmonary bypass (p less than .001), an effect that persisted for two hours after stopping the infusion. In the CGS-13080-treated group, plasma 6-keto-prostaglandin F1 alpha levels significantly increased over time (p less than .03) and were somewhat higher when compared with those in the placebo-treated group. This observation suggests that an "endoperoxide shunt" may have occurred. In the control group, an inverse correlation between platelet count and level of thromboxane B2 per platelet following in vitro thrombin stimulation (r = .5, p less than .001) was apparent, but there was no correlation between these two variables (r = .18, p less than .10) in the CGS-13080-treated group. No adverse hemodynamic or other effects attributable to CGS-13080 occurred during or immediately following cardiopulmonary bypass. These results suggest that CGS-13080 is an effective inhibitor of thromboxane B2 production during cardiopulmonary bypass in dogs and has no adverse physiological effects.


This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
S. A Hassantash, G. R Omrani, N. Givtaj, and M. Afrakhteh
Pharmacological Prevention of the Deleterious Effects of Cardiopulmonary Bypass
Asian Cardiovasc Thorac Ann, June 1, 2007; 15(3): 218 - 224.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1986 by The Society of Thoracic Surgeons.