The Annals of Thoracic Surgery, Vol 42, 218-219, Copyright © 1986 by The Society of Thoracic Surgeons
JS Donahoo, MJ Lechman and H MacVaugh 3d
A method of controlling a problematic aortotomy suture line using an onlay
patch of polytetrafluoroethylene (Gore-Tex) is described. This method has
been used successfully in several instances with good control of bleeding
and no complications.