ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peniston, C. M.
Right arrow Articles by Salerno, T. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peniston, C. M.
Right arrow Articles by Salerno, T. A.

The Annals of Thoracic Surgery, Vol 41, 473-477, Copyright © 1986 by The Society of Thoracic Surgeons


ARTICLES

The effects of cardioplegic arrest on right atrial function

CM Peniston, PA Spence, N Mihic, AK Jabr, M McLennan, V Yap and TA Salerno

Atrial electrical and mechanical activity persists during cardioplegic arrest. It has been postulated that atrial ischemia may occur and cause deterioration in atrial function. This study was designed to assess the effect of cardioplegic arrest on right atrial function. Twenty-one pigs were placed on cardiopulmonary bypass (CPB), and the right atrium was isolated from the circulation by snaring both venae cavae and incising the coronary sinus. The tricuspid valve was closed through a small right ventriculotomy, and baseline atrial function was assessed using a compliant balloon in the atrium. Fourteen pigs underwent one hour of cardioplegic arrest (7 with cardioplegia alone [CCA group] and 7 with the addition of topical hypothermia [CCA + TH group]) followed by one hour of normothermic reperfusion. Seven other pigs were placed on CPB for the same period of time (CPB group). Atrial electrical and mechanical activity persisted at 45 beats per minute in the CCA group but was virtually abolished in the CCA + TH group. Cardioplegic arrest caused considerable deterioration in right atrial function (developed pressure, 18.9 +/- 0.8 [baseline] versus 14.1 +/- 0.7 mm Hg; p less than 0.05; first derivative of atrial pressure [dP/dt], 187 +/- 19 versus 134 +/- 25 mm Hg per second; p less than 0.05; 60 minutes of reperfusion and balloon volume of 20 ml). It was not affected by topical cooling. Right atrial developed pressure was maintained, but dP/dt was significantly reduced in the CPB group. This study suggests that cardioplegic arrest does not protect the atrium.


This article has been cited by other articles:


Home page
ChestHome page
A. Pernat, M. H. Weil, S. Sun, W. Tang, H. Yamaguchi, and J. Bisera
Atrial Function During Cardiac Arrest Caused by Ventricular Fibrillation
Chest, April 1, 2000; 117(4): 1118 - 1123.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1986 by The Society of Thoracic Surgeons.