ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Watkins, L.
Right arrow Articles by Reid, P. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Watkins, L., Jr
Right arrow Articles by Reid, P. R.

The Annals of Thoracic Surgery, Vol 37, 60-66, Copyright © 1984 by The Society of Thoracic Surgeons


ARTICLES

The treatment of malignant ventricular arrhythmias with combined endocardial resection and implantation of the automatic defibrillator: preliminary report

L Watkins Jr, EV Platia, MM Mower, LS Griffith, M Mirowski and PR Reid

Fourteen patients with refractory ventricular tachyarrhythmias were treated with combined endocardial resection and implantation of the automatic defibrillator. There were 11 men and 3 women with a mean age of 53 years (range, 41 to 58 years). All patients had coronary artery disease; the mean ejection fraction was 26%, and the mean number of cardiac arrests was 2.6. Programmed electrical stimulation induced sustained ventricular tachycardia in 13 patients and nonsustained ventricular tachycardia in 1. Operative endocardial mapping in the 13 patients with sustained ventricular tachycardia demonstrated a septal focus of early activation in 9 patients and a nonseptal site in 4. Following resection, sustained ventricular tachycardia could not be reinduced. There was 1 operative death. Programmed electrical stimulation performed one month after operation induced ventricular tachycardia in 5 patients, but tachycardia could not be induced in the other 8 survivors. The longest follow-up was 32 months; the average was 17 months. There were 2 late deaths. One patient died of myocardial infarction and 1 of pulmonary edema following a routine cholecystectomy. In another patient, late ventricular tachycardia developed but was automatically terminated by the implanted defibrillator. These results suggest that endocardial resection combined with implantation of the automatic defibrillator may offer the greatest protection yet available to patients with malignant ventricular tachyarrhythmias.


This article has been cited by other articles:


Home page
CirculationHome page
P. C. Fotuhi, R. E. Ideker, S. F. Idriss, R. L. Callihan, R. G. Walker, and E. U. Alt
Influence of Epicardial Patches on Defibrillation Threshold With Nonthoracotomy Lead Configurations
Circulation, November 15, 1995; 92(10): 3082 - 3088.
[Abstract] [Full Text]


Home page
VASC ENDOVASCULAR SURGHome page
E. S. Yee
Automatic Implantable Cardioverter Defibrillators: Surgical Approaches for Optimal Function
Vascular and Endovascular Surgery, November 1, 1989; 23(6): 458 - 463.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1984 by The Society of Thoracic Surgeons.